• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
电网畸变不平衡条件下基于MAF-ANF的谐波检测方法研究
Research on harmonic detection method based on MAF-ANF in unbalanced and distorted network voltage
Received:December 28, 2017  Revised:December 28, 2017
DOI:
中文关键词: 有源电力滤波器  畸变不平衡  滑动平均滤波器  自适应陷波滤波器  谐波检测
英文关键词: Active power filter  unbalanced and distorted  moving average filter  adaptive notch filter  harmonic detection
基金项目:国家重点研发计划(2017YFB0903100)
Author NameAffiliationE-mail
Zhang Guorong HFUT,School of electrical and automation engineering zhanggrcao@163.com 
Deng Kaiwen* HFUT,School of electrical and automation engineering 913609537@qq.com 
Xie Runsheng HFUT,School of electrical and automation engineering 382437352@qq.com 
Wu Feixiang HFUT,School of electrical and automation engineering 1913966973@qq.com 
Wei Wei HFUT,School of electrical and automation engineering 2580700930@qq.com 
Hits: 1916
Download times: 761
中文摘要:
      有源电力滤波器( Active Power Filter,APF) 补偿电流检测环节对其补偿性能有着重要的影响。三相电网电压不对称且畸变时,传统的p-q法和ip-iq法无法准确实现对负荷综合补偿。为此本文引入基于滑动平均滤波器-自适应陷波滤波器(MAF-ANF)的方法实现对非理想电网电压条件下网侧电压的处理,得到平衡无畸变的电网电压,并对负载电流处理,得到准确的基波电流正序分量。然后对传统p-q法进行改进,得到了基于MAF-ANF的谐波检测方法,该方法较传统方法谐波检测精度提高,取得了更好的补偿效果。最后通过Simulink仿真证明了在非理想电网电压条件下所提检测算法的正确性和有效性。
英文摘要:
      The detection of compensation current has an important impact on the performance of active power filter.The traditional method of p-q and ip-iq can not be accurately achieve compensation of load with the unbalanced and distorted three-phase voltage. In this paper, the method of based on MAF-ANF is introduced which processes the distorted grid voltage in order to obtain an undistorted and balanced voltage. The load current is also processed to get the correct fundamental positive component. The traditional p-q method is improved, and the harmonic detection method based on MAF-ANF is deduced. This method improves the accuracy of harmonics detection and obtains better compensation effect. Finally, the correctness and effectiveness of the proposed detection algorithm under the condition of non ideal grid voltage are proved by simulation.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd