• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
考虑同调机组的电力系统主动解列断面搜索方法*
A searching method for power system controlled splitting sections considering coherent generators
Received:December 28, 2017  Revised:December 28, 2017
DOI:
中文关键词: 主动解列控制  断面搜索  Dinic算法  同调机组
英文关键词: active island control,island surfaces search,dinic algorithm,coherent generator
基金项目:内蒙古自治区高等学校科学研究项目(NJZC17514)
Author NameAffiliationE-mail
Tian Sujian* Baotou Vocational Technical College 3291976277@qq.com 
Yang Yue State Grid Jibei Electric Power Company Limited Qinhuangdao Power Supply Company m18233560363@163.com 
Hits: 1598
Download times: 542
中文摘要:
      将电力系统解列断面搜索问题转化为单目标多约束优化问题,提出了一种考虑同调机组的解列断面搜索新方法。节点间电抗值的大小反映了其电气连接强弱程度。首先以节点间线路电抗值为线路权值,利用Dijkstra算法计算同调机群中发电机之间最小电抗连接线路,得到同调机组连通图,之后用prim算法得到同调机组连通图的最小生成树,并将其等值为一个节点,从而保证电力孤岛内机组连通性。最后利用Dinic算法求得非同调机群间最小潮流割集,得到最优解列断面。对经典IEEE-39节点系统进行算例仿真,验证了文中所提出方法能够快速准确定位解列断面。
英文摘要:
      the search of power system controlled islanding surfaces problem is transformed into a single-objective multi-constraint optimization problem, and a new searching method for power system controlled islanding surfaces considering coherent generators is proposed. The magnitude of the reactance between nodes reflects the electrical contact degree of the two nodes, and the reactance value between the nodes is used as the line weight. The Dijkstra algorithm is used to calculate the minimum reactance value between the generator in the coherent generators group and get the coherent generators connection diagram. The prim algorithm is used to get the minimum spanning tree of the coherent generators connection diagram, The minimum spanning tree is equaled as a node, thus ensuring the connectivity of the generators in the island. The Dinic algorithm is used to obtain the minimum power flow cutset between non-coherent generators groups, and the optimal solution of power system controlled islanding surfaces is obtained. The simulation of the IEEE-39 node system verify that this method can determine the position of islanding surfaces quickly and accurately.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd