基于相电流特征的配电网单相断线区段定位新方法
A novel fault segment location method of single-phase disconnection fault in distribution network based on phase current characteristics
Received:December 29, 2017  Revised:December 29, 2017
DOI:
中文关键词: 配电网  单相断线  故障定位  相电流
英文关键词: distribution  network, single-phase  disconnection fault, fault  segment location, phase  current
基金项目:陕西省重点研发计划项目 (2017GY-189); 西安邮电大学“西邮新星”科技团队计划项目。
Author NameAffiliationE-mail
YAN XUEWEN* Xi''an University of Posts and Telecommunications yanxwxupt@163.com 
GAO WEI Xi''an University of Posts and Telecommunications gaowei@xupt.edu.cn 
ZHANG WENWEN Xi''an University of Posts and Telecommunications 56472690@qq.com 
DONG JUN Xi''an University of Posts and Telecommunications 16615157@qq.com 
Hits: 2068
Download times: 521
中文摘要:
      由于雷击等原因,配电网单相断线故障时有发生。为了避免断线故障导致电机损坏等事故,本文基于相电流特征提出了一种断线故障区段定位新方法。首先利用序网络分析了配电网发生断线故障后的相电压、电流特征,然后根据相电压特征构造了启动判据和故障选相判据,根据相电流相关系数构造了区段定位识别判据。所提出的方法具有灵敏度高、通信量小的优点,PSCAD仿真验证了该方法的有效性。
英文摘要:
      As a result of lightning and other reasons, distribution network single-phase disconnection fault always occurs. In order to avoid rotor broken and other accidents which is caused by single-phase disconnection fault, this paper presents a new method of fault location based on phase current characteristics. Firstly, the phase voltage and current characteristics of the distribution network are analyzed by using the sequence network. Then, the initiation criterion and the fault phase selection criterion are proposed according to the phase voltage characteristics. Finally, fault segment location criterion is put forward based on phase current correlation coefficient. The proposed method is high sensitive and need low communication. Simulations on PSCAD prove the effectiveness of the method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd