文章摘要
电流互感器检定装置多工位输出一致性研究*
Multiplexing Output Consistency Research for Current Transformer Verification Device
Received:January 11, 2018  Revised:January 11, 2018
DOI:
中文关键词: 电流互感器  检定装置  多工位输出一致性
英文关键词: current transformer  verification device  multiplexing output consistency
基金项目:
Author NameAffiliationE-mail
Xu Erqiang* State Grid Henan Electric Power Research Institute Metrology Center 13503718309@163.com 
Hits: 1438
Download times: 513
中文摘要:
      多工位输出一致性指标,是电流互感器检定装置的重要技术指标。本文基于互感器误差测试理论,提出了具体试验方案,测量了核查互感器在工位轻载和满载状态下的基本误差,分析了装置多工位输出一致性。数据表明:装置的多工位输出一致性与工位状态无关,随着核查互感器二次负荷的增大而增大,装置多工位对测量结果的比差、角差影响量相同。最后得出了装置多路输出一致性指标为30%误差限值的结论。这对规范多工位电流互感器检定装置的制造、保证互感器误差测量的准确、可靠具有推广应用价值。
英文摘要:
      Multiplexing output consistency is an important technical indicators for current transformer verification device. Based on current transformer error experiment theories, Testing program is introduced, the basic error is measured for checked current transformer under the workstation status of light load and full load, and multiplexing output consistency is analyzed for the verification device in this paper. The result data show that multiplexing output consistency has nothing to do with current transformer workstation status, it increases with the secondary load volume increase of checked current transformer and multiplex device has the same influence on amplitude error as phase error. Finally conclusion is drawn that the index of multiplexing output consistency for the device is 30% of maximum permissible error value. It will standardize the manufacture of current transformer verification device and more guarantee measure accuracy and reliability for current transformers. These have certain the value of popularization and application.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd