文章摘要
基于绝对延时的DCCT异地同步现场校准方法及不确定度研究
Research on field calibration method and uncertainty of DCCT remote synchronization based on absolute delay
Received:February 01, 2018  Revised:February 01, 2018
DOI:
中文关键词: 异地同步  绝对延时  交错并联  不确定度  直流分量  
英文关键词: Special place synchronization  absolute delay  interlaced parallel  uncertainty  DC component  
基金项目:中国南方电网公司科技项目(YNKJ00000124),云南省人培项目(KKSY20160428)。
Author NameAffiliationE-mail
zhumengmeng* Yunnan power grid co. Ltd electric power research institute 396923800@qq.com 
lincong Yunnan power grid co. Ltd electric power research institute 371223910@qq.com 
曹敏 Yunnan power grid co. Ltd electric power research institute 52@163.com 
luoqiang Jiangsu LingChuang Electric Automation Co., Ltd. luoqiangmail@163.com 
zhuquancong Yunnan power grid co. Ltd electric power research institute 95015655@qq.com 
tianxincui Faculty of Electric Power Engineering, Kunming University of Science and Technology 1105479731@qq.com 
Hits: 1799
Download times: 712
中文摘要:
      直流电流互感器(DCCT)的准确性合格与否是其状态评估及现场投产验收的重要依据,对直流输电保护控制的稳定运行起着极其重要作用。但现场校准工作受试验方法、现场校准设备及关键技术等因素影响开展并不顺利。本文结合换流站实际情况,提出一种基于绝对延时的DCCT异地同步现场校准方法,针对DCCT绝对延时的现场测试进行,并研制出高准确度直流互感器现场同步校准系统。文章构建了校准系统不确定度分析模型,确保了现场校准结果的可信度。所述试验方法在±500kV永富直流工程直流电流互感器现场试验中得到应用与验证,为我国换流站直流电流互感器现场测试提供参考依据。
英文摘要:
      The accuracy of DC current transformer (DCCT) is an important basis for its state evaluation and on-site acceptance. It plays an important role in the stable operation of HVDC protection and control. However, the field calibration is not successfully carried out by the factors such as the test method, the field calibration equipment and the key technology. Combined with the actual situation of converter station, this paper proposes a DCCT based asynchronous field synchronous calibration method based on absolute delay. Aiming at the field test of DCCT absolute delay, we develop a high-accuracy DC transformer field synchronous calibration system. In this paper, an uncertainty analysis model of the calibration system is built to ensure the reliability of the calibration results.The test method is applied and verified in the field test of DC current transformer of ±500kV Yongfu DC project, providing reference for the field test of DC current transformer of converter station in China.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd