除颤器分析仪校准装置的研究
Development of Calibration System for Defibrillator Analyzers
Received:April 09, 2018  Revised:April 24, 2018
DOI:
中文关键词: 除颤器分析仪  除颤脉冲能量  能量测试  计量溯源系统
英文关键词: defibrillator analyzer, defibrillation pulse energy, energy testing, metrological traceability system
基金项目:医学诊疗设备计量标准及溯源体系研究
Author NameAffiliationE-mail
Zhang Huanghui School of instrumentation science and opto-electronics engineering,BeiHang University
Fujian Metrology Institute 
fjzhh52@163.com 
Shao Haiming* National Institute of Metrology shaohm@nim.ac.cn 
Zhao Wei National Institute of Metrology zhaowei@nim.ac.cn 
Wang Jiafu National Institute of Metrology jiafu.wang@nim.ac.cn 
Pan Jinqiu Beijing Information Science and Technology University jinqiupan@outlook.com 
Zhao Yeming Beijing Information Science and Technology University 906034735@qq.com 
Hits: 1938
Download times: 748
中文摘要:
      除颤器作为一种心脏急救设备,临床应用事关患者的生命安全,为保证除颤器各项参数的准确可靠,必须通过检测仪器对其进行定期检测。为确保电除颤脉冲能量的可溯源性和可靠性,本文介绍了一种用于校准除颤器分析仪的集成“源”“表”装置的研制,该装置的设计是为了产生和测量典型的单相和双相除颤脉冲波形。通过同步采样脉冲电压和电流并积分计算能量,实现了从0.1 J到360 J的脉冲能量测量,测量误差优于±(0.2%E+0.5) J。
英文摘要:
      As a kind of cardiac emergency apparatus, the clinical application of defibrillator is related to the patient's life safety. In order to ensure the accuracy and reliability of the electric shock parameters of the defibrillator, it is necessary to check the equipment regularly. To ensure the traceability and reliability of the electrical defibrillation pulse energy, this paper presents the development of an integral source-meter setup for the calibration of defibrillator analyzers, that has been designed to generate and measure both typical monophasic and biphasic waveforms. By synchronously sampling the pulse voltage and current for integral calculation the energy, the 0.2%E+0.5 J uncertainties of pulse energy from 0.1 J to 360 J are achieved.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd