基于改进虚拟磁链的dq谐波检测方法
Dq harmonic detection method based on improved virtual flux
Received:August 06, 2018  Revised:August 06, 2018
DOI:10.19753/j.issn1001-1390.2019.020.010
中文关键词: 电压畸变  谐波检测  虚拟磁链  二阶广义积分  频率自适应
英文关键词: voltage  distortion, harmonic  detection, virtual  flux, Second-order  generalized integrator, frequency  self-adaptation
基金项目:江苏省研究生科研与实践创新项目(SJCX18-0700);
Author NameAffiliationE-mail
Meng Fanting School of Electrical Engineering&Automation,Jiangsu Normal University mft0520@163.com 
Jia Chuansheng* School of Electrical Engineering&Automation,Jiangsu Normal University Ljshi1981@126.com 
Liu Zhenzhong School of Electrical and Power Engineering,China University of Mining and Technology TS17130162P3@cumt.edu.cn 
Hits: 1546
Download times: 577
中文摘要:
      为了提升传统dq谐波检测法对网侧电压畸变的应对能力,提出一种基于复合二阶广义积分器的虚拟磁链定向的谐波检测方法。该方法采用虚拟磁链作为同步参考坐标系锁相环的改进环节,利用复合二阶广义积分器替代常规低通滤波器,消除了传统dq谐波检测方法由于三相电网电压不对称和畸变等恶劣工况造成的检测误差,并能准确锁定电网相位角和频率。仿真和实验结果表明,改进后的谐波检测方法不受电网不平衡和波形畸变的影响,所得基波正序电流基本不存在畸变,且能够准确跟踪频率的变化,证实了本文所提出的基于复合二阶广义积分虚拟磁链定向的谐波检测方法的有效性。
英文摘要:
      In order to improve the ability of traditional dq harmonic detection method to respond to grid-side voltage distortion, a virtual flux-oriented harmonic detection method based on composite second-order generalized integrator is proposed. The method uses the virtual flux as an improvement of the Synchronous Reference Frame Phase-locked Loop , and replaces the conventional low-pass filter with the composite second-order generalized integrator, which eliminates the detection error of the traditional dq harmonic detection method that due to the harsh conditions of voltage asymmetry and distortion of the three-phase power grid, and the grid phase angle and frequency can be accurately locked. The simulation and experiment results show that the improved harmonic detection method is not affected by the imbalance and distortion of the power grid, the fundamental wave positive sequence current has no distortion,and it can accurately track changes of frequency. It proves that the virtual flux directional harmonic detection method based on composite second order generalized integrator proposed in this paper effectiveness.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd