文章摘要
Y/Δ接线电力变压器内部异常励磁电流辨识
Identification of excitation current for internal anomaly of Y/Δ connected power transformer
Received:August 07, 2018  Revised:August 07, 2018
DOI:
中文关键词: 变压器  直流扰动  匝间短路  励磁电流辨识
英文关键词: Transformer  DC disturbance  Inter-turn short circuit  Excitation current identification
基金项目:国家自然科学基金项目(51507027);吉林科技创新发展计划项目(20166014)
Author NameAffiliationE-mail
Pan Chao Northeast Electric Power University 3422925972@qq.com 
Han Tao* Northeast Electric Power University 1017363084@qq.com 
Hits: 1108
Download times: 625
中文摘要:
      本文针对Y/Δ接线电力变压器,基于时域场路耦合模型提出一种励磁电流参数辨识方法。建立磁场-电路耦合模型,基于能量扰动原理计算动态电感与时域电流两个状态变量,在此基础上利用端口电气信息研究变压器励磁电流参数的辨识方法。通过研究交直流混杂、匝间短路情况下的变压器电磁特性,结合变压器励磁饱和状态,总结励磁电流在不同异常状态下的变化规律。搭建220V三相组式变压器动模实验平台,在不同直流扰动、不同电压等级匝间短路条件下,利用励磁参数辨识模块辨识励磁电流,并将仿真结果与实验数据进行对比,验证仿真模型的正确性。
英文摘要:
      In this paper, an excitation current identification method is proposed based on the time-domain field-circuit coupled model. The electromagnetic coupling state equation of transformer is established. Based on energy disturbance principle, two state variables of dynamic inductance and time-domain current are calculated, the identification method of transformer excitation current parameters is studied by port electrical information. The electromagnetic characteristics of transformer under AC/DC hybrid and inter turn short circuit are studied, and combined with saturation state of transformer, the changing rule of excitation current under different conditions is summarized. The experiment platform of 220V three-phase group transformer is established,under different DC disturbance and inter-turn short circuit with different voltage levels, the excitation current is identified by excitation parameter identification module. And the simulation results are compared with the experimental data,the correctness of the simulation model is verified.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd