• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
高压内置变压器零序涌流特性研究*
Research on zero sequence inrush characteristic of high-voltage built-in transformer
Received:August 23, 2018  Revised:August 23, 2018
DOI:10.19753/j.issn1001-1390.2019.024.009
中文关键词: 高压内置变压器  零序涌流特性  结构参数  应对方法  
英文关键词: high-voltage  built-in  transformaer, zero  sequence inrush  characteristic, structural  parameters, response  options
基金项目:
Author NameAffiliationE-mail
YAO Nan State Grid Henan Electric Power Company Nanyang Power Supply Company 13703778500@139.com 
SHANG Guangwei State Grid Henan Electric Power Company Nanyang Power Supply Company dabaicai61@163.com 
GENG Jinfeng Henan Electric Power Testing and Research Institute 540327446@qq.com 
LIU Yao* Henan Electric Power Testing and Research Institute 540327446@qq.com 
Hits: 1478
Download times: 562
中文摘要:
      变压器的零序涌流不再偏向于时间轴一侧且二次和三次谐波含量更高。与普通结构变压器相比,高压内置变压器由于将高压侧内置,在结构参数上呈现互漏感较小而自漏感较大的特点。此外,高压内置变压器能够产生幅值更大,零序含有率更高且衰减较为缓慢的励磁涌流。通过仿真模拟了不同因素对涌流特性的影响,得到高压内置变压器更容易导致零序电流保护误动的结论,并根据实际经验给出了初步的应对方法。
英文摘要:
      The zero sequence inrush of transformer is no longer biased on the side of the time axis ,and its secondary and three harmonic contents are higher. Compared with ordinary structure transformer, the high-voltage built-in transformer has smaller mutual leakage inductance and larger self-leakage inductance in structure parameters because its high-voltage side near the core. In addition, the high-voltage built-in transformer can produce larger amplitude, higher zero-sequence containing rate and slower attenuation of inrush current. By simulating the influence of different factors on inrush current characteristics, the conclusion that high-voltage built-in transformer is more likely to cause zero sequence current protection maloperation is obtained, and the preliminary countermeasures are given according to practical experience.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd