• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于αβ坐标系的电流型PWM整流器有源阻尼控制
Active Damping Control of Three-phase Current Source PWM Rectifierunder αβ Coordinates
Received:August 30, 2018  Revised:August 30, 2018
DOI:10.19753/j.issn1001-1390.2019.021.016
中文关键词: 电流型PWM整流器  LC滤波器  αβ坐标系  有源阻尼
英文关键词: PWM  current source  rectifier, LC  filter, αβ coordinate  system, active  damping
基金项目:
Author NameAffiliationE-mail
Li Lianbing Hebei University of Technology,School of Artificial Intelligence lilianbing@hebut.edu.cn 
Wang Linglong* Hebei University of Technology,School of Artificial Intelligence linglong930804@163.com 
Yue Donghua Hebei University of Technology,School of Artificial Intelligence 13820889772@163.com 
Zhu Yazun Hebei University of Technology,School of Artificial Intelligence zhuyazun@126.com 
Chen Li Hebei University of Technology,School of Artificial Intelligence 1012372094@qq.com 
Hits: 1571
Download times: 537
中文摘要:
      三相电流型PWM整流器交流侧常采用LC滤波器来滤除谐波和辅助开关器件换流,但LC滤波器具有谐振特性,存在谐振尖峰,当控制量或负载变化时会引起系统暂态振荡以及网侧电流谐波畸变。针对上述问题,提出了一种基于αβ坐标系的电感电压反馈的有源阻尼控制方法。该方法的实现不需要进行锁相环控制和dq坐标解耦,电感电压反馈的有源阻尼控制可以有效抑制LC滤波器谐振尖峰。最后通过MATLAB仿真和实验验证了所提方法的有效性和实用性。
英文摘要:
      LC filter and aided switch devices are often used in AC side of three-phase pulse width modulation (PWM) current source rectifier (CSR). Although LC filter can filter harmonics effectively, it has the feature of resonance and exists resonance peak. The system oscillatory transient and supply current waveform distortion are caused by those, when the input of the system or load changed. Aiming at the above problems, a method of active damping control of the inductor voltage feedback under αβ coordinates is proposed. It does not require phase-locked loop control or dq coordinate decoupling. Combining with active damping control of inductive voltage feedback, the method is implemented under the αβ coordinate to suppresses LC filter resonance peak effectively. Finally, the effectiveness and practicability of the proposed method are verified by MATLAB simulation and experimental.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd