负荷对接地故障转移消弧技术的影响
Effects of Load on Arc-suppression Method Based on Grounded-Fault Transfer Device
Received:September 01, 2018  Revised:September 01, 2018
DOI:10.19753/j.issn1001-1390.2019.023.004
中文关键词: 消弧  接地故障转移转移消弧  中性点非有效接地  负荷阻抗
英文关键词: arc-suppression, arc-suppression  method based  on grounded-fault  transfer device, non-effectively  grounded neutral, load  impedance
基金项目:
Author NameAffiliationE-mail
Chen Ying State Grid Sichuan Electric Power Research Institute 3400567464@qq.com 
Chen Kunyi* Sichuan university ky0304528@163.com 
Xiao Xianyong Sichuan university xiaoxianyong_@163.com 
Yang Lin State Grid Sichuan Electric Power Research Institute 13408548341@163.com 
Fan Songhai State Grid Sichuan Electric Power Research Institute 879238566@qq.com 
Chen Shaoqing State Grid Sichuan Electric Power Research Institute chenshaoqing_1@163.com 
Hits: 1389
Download times: 610
中文摘要:
      为了分析负荷对接地故障转移消弧技术的影响,提出了一种接地故障转移消弧技术等效模型。利用该模型对接地故障转移消弧装置的电流转移性能和恢复电压抑制能力进行了研究,给出了接地故障转移消弧技术受负荷影响的规律。研究结果表明:接地故障转移消弧装置的电流转移性能受负荷影响较大,在大负荷、小接地电阻的情况下可能出现不能转移故障点电流的情况,甚至有增大故障点电流的可能;故障转移消弧装置对恢复电压有较强的抑制能力,且受负荷的影响较小。研究结果为接地故障转移消弧装置控制方法的改进提供了理论依据。
英文摘要:
      In order to analyze the effects of load on arc-suppression method based on grounded-fault transfer device, an equivalent model of the arc-suppression method was proposed. The performance for transferring fault current and the capacity for controlling recovery voltage of the transfer device were studied by using the proposed model, and the laws of the arc suppression method affected by load was given. The results show that it has a great effect by load on the performance for transferring fault current. In the case of large load and small ground resistance, it is possible that the fault current cannot be transferred, or even the fault current can be increased. In addition, the analysis results indicated that the ground fault transfer device has a strong ability to restrain the recovery voltage, and is less affected by the load. The results provide a theoretical basis for improving the control method of the arc suppression device.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd