文章摘要
复合I型绝缘子的直流鸟粪闪络特性研究
Study on the bird streamer flashover characteristics of I-type composite insulator string
Received:September 16, 2018  Revised:October 03, 2018
DOI:10.19753/j.issn1001-1390.2020.02.011
中文关键词: 鸟粪闪络  电晕放电  空间位置  击穿电压  击穿场强
英文关键词: bird streamer, corona discharge, spatial position, breakdown voltage, breakdown field strength
基金项目:中央高校基本科研业务费专项资金资助项目(2015ZD19)
Author NameAffiliationE-mail
Wang Huaqian* North China Electric Power University 499254818@qq.com 
Wang Shenghui China Electric Power Research Institute 499254818@qq.com 
Yang Guanghua North China Electric Power University 499254818@qq.com 
Deng Changyu North China Electric Power UniversityBaoding 499254818@qq.com 
Lv Fangcheng North China Electric Power University 499254818@qq.com 
Hits: 2182
Download times: 698
中文摘要:
      为减少鸟害事故发生,提高线路运行可靠性,有必要对鸟粪闪络特性进行研究。本实验采用了浸渍有鸟粪模拟液的棉布条来模拟鸟粪,以复合I型绝缘子为研究对象,试验模拟研究了在直流电压下,鸟粪从均压环正上方和侧上方下落时,其空间位置对起晕电压、击穿电压和击穿场强的影响。研究表明,当模拟鸟粪与均压环距离增大时,击穿电压升高,击穿场强会随着间隙距离的增大而逐渐降低,接近于棒-棒间隙的击穿电场强度。最后,利用COMSOL有限元仿真软件进行了计算。试验和仿真结果对输电线路的建设和维护有一定的参考价值。
英文摘要:
      In order to reduce bird damage and improve the reliability of power system, it is necessary to study the bird steamer flashovers. A cotton strip impregnated with the bird streamers simulating liquid was used to simulate bird streamers in this experiment. And the I-type composite insulator string was used as the research object. During the test, the relationship between the spatial position and the corona onset voltage and the breakdown voltage was studied when the bird streamers fell from directly above and to the side of the grading ring. Studies have shown that when the distance between the bird streamers simulation strip and the grading ring is getting larger and larger, the breakdown voltage is getting higher and higher. The breakdown field strength gradually decreases as the gap distance increases, the value is close to the breakdown electric field intensity with the rod-rod gap. Finally, the simulation model is established by COMSOL. The experimental and simulation results provide a reference for the construction and prevention of transmission lines.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd