• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
±1100kV吉泉线并行交流特高压线路施工中电磁感应及接地分析
Research on parallel line induction of 1000 kV Anhui-to-East UHV AC line and suppression measure
Received:September 19, 2018  Revised:September 19, 2018
DOI:10.19753/j.issn1001-1390.2019.021.017
中文关键词: 特高压交流  电磁耦合  静电感应电压  电磁感应电流  接地方案
英文关键词: ultra  high voltage, electromagnetic  coupling, electrostatic  induction voltage, electromagnetic  induction current, earthing  scheme
基金项目:
Author NameAffiliationE-mail
liuyong State Grid Anhui Electric Power Co., Ltd 619366034@qq.com 
liuchengzhi State Grid Anhui Electric Power Co., Ltd 619366034@qq.com 
Ren Hongxin* Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense,North China Electric Power University 619366034@qq.com 
sunminggang State Grid Anhui Electric Power Co., Ltd. Construction Company 619366034@qq.com 
yangzhonglv State Grid Anhui Electric Power Co., Ltd. Construction Company 619366034@qq.com 
guoxin Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense,North China Electric Power University 619366034@qq.com 
lihuiqi Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense,North China Electric Power University 619366034@qq.ocm 
Hits: 1804
Download times: 610
中文摘要:
      在建的±1100 kV吉泉输电线路近距离并行皖电东送特高压1000 kV交流输电线路,由于线路间的电磁耦合使得吉泉线在施工中面临严重的感应电问题。本文建立了三维输电线路的矩量法模型,计算分析了并行双回特高压交流线路施工时的感应电压和感应电流,对影响静电感应电压和电磁感应电流的主要因素进行了分析。最后,针对施工中的不同接地方案进行了研究,提出了施工中建议的接地方案。
英文摘要:
      The Jiquan ±1100kV transmission line in the construction close multiple parallel Anhui-to-East UHV 1000kV AC transmission lines. Since the electromagnetic coupling between the lines makes the Jiquan transmission line in the construction facing serious problems of induction. A three-dimensional moment method model for transmission lines is established in this paper. And the induced voltage and induced current of the Jiquan transmission line under construction, which is parallelling with a double-circuit UHV AC line, are calculated and analyzed. The main factors affecting electrostatic induction voltage and electromagnetic induction current are also analyzed. In the end, a study is conducted on different grounding schemes during construction and the proposed grounding scheme are put forward.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd