• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
智能电能表过载运行时计量性能异常分析和改进策略
ANALYSIS AND IMPROVEMENT STRATEGY FOR ABNORMAL METROLOGICAL PERFORMANCE OF SMART ELECTRIC METERS IN OVERLOAD CONDITION
Received:October 26, 2018  Revised:October 26, 2018
DOI:10.19753/j.issn1001-1390.2019.024.022
中文关键词: 智能电能表  电流过载  溢出
英文关键词: smart electric meters current overload overflow
基金项目:国网公司科技项目《基于典型环境条件下的电能计量设备性能验证平台技术研究》 项目编号5442JL160013
Author NameAffiliationE-mail
WANG Xiao-dong* Metrology Institute,China Electric Power Research Institute wangxiaodong@epri.sgcc.com.cn 
DUAN Xiao-meng Metrology Institute,China Electric Power Research Institute duanxiaomeng@epri.sgcc.com.cn 
Zhao-Yudong State Grid Liaoning Electric Power Company Limited 562053604@qq.com 
Wang-Shuang China Electric Power Research Institute wangshuang@epri.sgcc.com.cn 
Zhao-Ting China Electric Power Research Institute zhaoting@epri.sgcc.com.cn 
Hits: 1648
Download times: 632
中文摘要:
      智能电能表在实际运行过程中,有时会碰到电流过载(大于Imax)运行的情况,某些电能表在过载运行中会出现功率减小甚至反向的情况,并且当电流恢复到计量量程以内,电能表仍然处于异常状态。本文从智能电能表现场运行故障案例出发,仿真计量芯片中的ADC模型和滤波器的溢出效应,对上述两个现象从原理上进行解释,并给出解决方案,同时通过试验数据验证解决方案的正确性。针对过载后的电能表性能要求,给各省电力公司提出了相应的指导意见。
英文摘要:
      Current overload may happen during the actual operation of the smart electric meters. Once this happened, some meters may calculate a reduced power or even a reversed power, and when the current returns to the normal metering range, the meters may still behave abnormally.In this paper, based on the field operation failure case of smart electric meters, the paper simulates the overflow effect of ADC model and filter in the measurement chip, explains the above two phenomena in principle, and gives the solution, and verifies the correctness of the solution through experimental data。Put forward corresponding guidance to the provincial electric power company under the overload condition.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd