基于暂态电流固态能量的故障识别分析
Fault identification analysis of power line based onEMD decomposition method
Received:October 29, 2018  Revised:October 29, 2018
DOI:
中文关键词: 特高压线路  EMD分解法  暂态能量  EMTP
英文关键词: UHVStransmissionSlines, The  EMD decomposition  method, Transient  energy, EMTP
基金项目:
Author NameAffiliationE-mail
Zhenbao Yang* Shenzhen Power Supply Bureau Co.,Ltd. 12100956@qq.com 
Zhenhua He Shenzhen Power Supply Bureau Co.,Ltd. 12100956@qq.com 
Hits: 1377
Download times: 647
中文摘要:
      针对电力系统特高压线路暂态故障,本文在固有模态能量分析法的基础上提出了一种基于暂态电流的故障分析法。由于EMD分解法具有良好的完备性和正交性,可通过相对能量系数分析故障过程暂态能量的大小,因此通过比较同一时刻、同一位置的三相线路暂态电流固有能量系数的相对大小就可以识别出故障相别及类型。在对该方法进行理论分析和EMTP模型搭建之后,仿真结果也表明该方法能够快速识别故障性质,对于保护功能的实现以及自动重合闸的逻辑设计均具有指导意义。
英文摘要:
      Aiming at the transient fault of SUHVStransmissionSlines in power system, a fault analysis method based on transient current is presented in this paper. As EMD decomposition method has good completeness and orthogonality, it can analyze the size of transient energy of fault process through the relative energy coefficient. Therefore, by comparing the relative size of the inherent energy coefficient of transient current of three-phase line at the same time and location, fault phase and type can be identified. After the theoretical analysis and EMTP model construction, the simulation results also indicate that the method can quickly identify the fault nature, which is of guiding significance for the realization of protection function and the logical design of automatic reclosing.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd