• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于求导法的dq变换结合形态学滤波的电压暂降检测方法
Single phase voltage sag detection method based on derivation αβ-dq transform method combined with morphological filter
Received:December 14, 2018  Revised:February 20, 2019
DOI:10.19753/j.issn1001-1390.2020.03.004
中文关键词: 求导法  电压暂降  αβ-dq变换  形态滤波  幅值相位
英文关键词: Derivation, voltage sag, αβ-dq transform, morphological filter, amplitude and phase
基金项目:吉林省科技厅科技发展计划重点科技研发资助项目(20180201010GX)吉林省发改委产业开发技术专项基金支持项目(2019C057-3)
Author NameAffiliationE-mail
Zhou Jun Northeast Electric Power University jlzhoujun@126.com 
Fu XiuLai* Northeast Electric Power University 2895479461@qq.com 
Li Shuguang Northeast Electric Power University 794265007@qq.com 
Hits: 1198
Download times: 493
中文摘要:
      电压暂降是电力系统中频繁出现的严重电能质量问题,而传统的电压暂降检测方法在实时性和精确性上仍有不足,对此提出一种基于形态学滤波器和求导法αβ-dq变换的单相电压暂降快速检测方法。详细分析了基于求导的αβ-dq变换法检测原理,通过比较不同结构元素的形态滤波器的性能,选取合适的结构元素的形态滤波器滤除系统谐波和噪声,提高算法的精确性。使用软件仿真分析该方法并通过使用该方法分析实验室搭建的模拟电压暂降模型采集到的数据进一步对该方法进行验证,结果表明该方法可以快速、准确地检测出电压暂降的幅值、持续时间和相位变化。
英文摘要:
      Voltage sag is a serious power quality problem which frequently occurs in power system, but traditional voltage sag detection methods still have deficiencies in rapidity and accuracy. So here propose a fast single-phase voltage sag detection method based on morphological filter combine with differential coefficient αβ-dq transform method. The principle of derivative αβ-dq transform method has been analyzed in detail, then choose appropriate morphological filter by comparing the ability of morphological filter with different structure element in order to filter harmonic and noise which generated by power system, so the accuracy of algorithm could be increased. Simulate and analyze this method by using computer software and then further validate this method by using it to analyse data collected by a simulation voltage sag data gathering module built in lab. All those consequence show that this method can detect the amplitude, the onset time and the phase of voltage sag quickly and accurately.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd