• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
突发短路试验中变压器振动监测系统的设计
Design of a vibration monitoring system for power transformer in short-circuit test
Received:December 20, 2018  Revised:December 20, 2018
DOI:10.19753/j.issn1001-1390.2020.09.017
中文关键词: 突发短路  变压器振动  绕组形变  分布式系统
英文关键词: Burst short circuit, vibration of power transformer, winding deformation, distributed System
基金项目:国网上海市电力公司电力科学研究院2018年科技项目(520940170028)
Author NameAffiliationE-mail
Liao Wei State Grid Shanghai Electric Power Research Institute, Shanghai liaoweicsu@126.com 
Tian Haoyang State Grid Shanghai Electric Power Research Institute, Shanghai tianhy1111@163.com 
Hu Min Department of Electrical Engineering, Shanghai Jiaotong University, Shanghai minhu520@vip.sina.com 
Chen Haikun Shanghai Shinan Electric Power (Group) Co., Ltd, Shanghai chenhk_001@163.com 
Yuan Xinfeng* Department of Electrical Engineering,Shanghai Jiaotong University,Shanghai 2765283920@qq.com 
Jin Zhijian Department of Electrical Engineering,Shanghai Jiaotong University,Shanghai zjjin@sjtu.edu.cn 
Hits: 1691
Download times: 494
中文摘要:
      突发短路试验能够对变压器的抗短路能力进行评估,而绕组在试验中是否发生形变是重要的判断标准。基于振动分析法的绕组状态检测技术具有灵敏度高、工作效率高等优点,但现有的变压器振动采集系统不能满足短路试验中对采集精度和防护标准的要求,文中设计了分布式变压器振动采集系统,在试验间内安装高防护等级、高精度的采集单元,将采样得到的振动信号就地转换为数字信号发送至控制室内的主控单元,避免短路试验中恶劣的电磁环境对采样信息产生干扰。后期可通过计算机对振动信号进行处理来分析绕组健康状态,目前系统已成功投入应用。
英文摘要:
      The short-circuit test can evaluate the short-circuit resistance of the transformer, and whether the winding is deformed during the test is an important criterion. The winding state detection technology based on vibration analysis has the advantages of high sensitivity and high working efficiency, but the existing transformer vibration acquisition system cannot meet the requirements of acquisition accuracy and protection standards in the short circuit test. In this paper, a distributed transformer vibration acquisition system is designed. A high-protection level and high-precision local unit is installed in the test room. The collected vibration signal is converted into a digital signal and sent to the main control unit in the control room to avoid the short-circuit test. The harsh electromagnetic environment interferes with the sampling information. In the later stage, the vibration signal can be processed by computer to analyze the health status of the winding. The system has been successfully put into use.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd