含T接逆变型分布式电源配电网的纵联保护方案
Pilot protection scheme for distribution network with T-connectedinverter interfaced distributed generation
Received:December 28, 2018  Revised:January 03, 2019
DOI:10.19753/j.issn1001-1390.2020.11.012
中文关键词: 逆变型分布式电源  T接线路  纵联保护  复合差动阻抗  配电网
英文关键词: inverter  interfaced distributed  generation, teed  line, pilot  protection, composite  differential impedance, distribution  network
基金项目:
Author NameAffiliationE-mail
Ming Xiaoyu College of Electrical Engineering and Information Technology, Sichuan University 401927737@qq.com 
Lv Feipeng* College of Electrical Engineering and Information Technology, Sichuan University 781144753@qq.com 
Yu Xiao College of Electrical Engineering and Information Technology, Sichuan University 1390371210@qq.com 
Wang Shanshan College of Electrical Engineering and Information Technology, Sichuan University 2532173979@qq.com 
Hits: 1628
Download times: 413
中文摘要:
      针对逆变型分布式电源(IIDG)T接方式接入配电网后传统三段式电流保护难以适用的问题,提出了一种含T接逆变型分布式电源配电网的纵联保护方案。该方案首先讨论了在低电压穿越期间IIDG采用恒功率控制策略对故障输出的影响;其次,通过定义复合差动阻抗并分析其在被保护馈线区内外故障的幅值差异,提出一种基于复合差动阻抗的含逆变电源T接配网的纵联保护原理;同时,为消除该保护原理在三相金属性短路故障时的死区,引入T型电流差动保护作为辅助判据。最后,在PSCAD/EMTDC仿真平台搭建了含IIDG的10kV配电网仿真模型,仿真结果验证了本文方案的合理性与有效性。
英文摘要:
      S:Aiming at the problem that traditional three-stage current protection is difficult to be applied after inverter interfaced distributed generation(IIDG) T-shaped access to distribution network, a pilot protection scheme for IIDG T connection distribution network is proposed. The effect of constant power control strategy on fault output during low voltage crossing is discussed. Secondly, by defining the composite differential impedance and analyzing the amplitude difference of the fault in and outside the protected feeder area, the pilot protection principle of the inverter interfaced distributed generation T connection network based on the composite differential impedance is proposed. At the same time, in order to eliminate the dead zone in the three-phase gold short circuit fault, the differential current protection of T-type transmission lines is introduced as the auxiliary criterion. Finally, a 10kV distribution network simulation model with IIDG is built on the PSCAD / EMTDC simulation platform. The simulation results prove that the scheme is reasonable and effective.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd