• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于双电源交叉供电动态电压恢复装置研究
Research on Dynamic Voltage Restoration Device Based on Double Bus Crossing Power Supply
Received:January 27, 2019  Revised:January 27, 2019
DOI:DOI: 10.19753/j.issn1001-1390.2020.10.020
中文关键词: 母线侧  交叉供电  动态电压恢复  并网
英文关键词: Bus,Cross  power supply,Dynamic  Voltage Recovery,Grid  connected
基金项目:国网江苏省电力有限公司镇江供电分公司项目(J20180296)
Author NameAffiliationE-mail
Sun Haibo State Grid Zhenjiang Power Supply Company,Jiangsu,Zhenjiang qitiandasheng001@126.com 
Zhou Jie* Jiangsu University 18352861173@163.com 
Huang Yonghong Jiangsu University hyh@ujs.edu.cn 
Tang Qian State Grid Zhenjiang Power Supply Company,Jiangsu,Zhenjiang jerrytq@163.com 
Hits: 1545
Download times: 449
中文摘要:
      针对负载侧多敏感设备同时发生电压暂降或中断时,多补偿设备同时工作导致设备间相互影响,降低电压恢复能力的问题,提出一种在母线侧集中补偿的新型大功率动态电压恢复装置结构。该结构采用将动态电压恢复器(DVR)与不间断电源(UPS)相结合,并基于双电源交叉供电方式,通过控制补偿装置的孤岛与并网运行模式的切换,伴随微网工作在孤岛运行模式、孤岛与并网相互切换方以及并网运行模式3种状态,实现两段母线的交叉供电,确保了微网中敏感负荷的供电可靠性。试验仿真表明,该结构能大大提高动态电压恢复装置的输出电压能力,实现了母线侧电压暂降与中断的长时间集中补偿,进一步提高了敏感负荷的供电可靠性。
英文摘要:
      Aiming at the problem that multi-compensation devices work at the same time when voltage sags or interruptions occur in load-side multi-sensitive devices, which results in the interaction between devices and reduces the voltage recovery ability, a new structure of high-power dynamic voltage recovery device with centralized compensation at bus-side is proposed. The structure combines dynamic voltage restorer (DVR) with uninterruptible power system (UPS), and based on double power supply mode, by controlling the switching of islanding and grid-connected operation modes of compensation devices, the micro-grid works in three states: islanding operation mode, islanding and grid-connected mutual switching mode and grid-connected operation mode, the cross-supply of two-section buses is realized, and the reliability of sensitive loads in the micro-grid is ensured. The simulation results show that the structure can greatly improve the output capacity of the device, realize the long-term centralized compensation of voltage sag and interruption at bus side, and further improve the reliability of power supply for sensitive loads.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd