• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于benders算法的两电压等级网络可用传输容量计算
Available Transfer Capability Determination of Two Voltage Levels Network Using Benders Algorithm
Received:February 13, 2019  Revised:February 13, 2019
DOI:10.19753/j.issn1001-1390.2020.14.006
中文关键词: 可用传输容量  N-1安全准则  Benders  网络重构
英文关键词: available transfer capability  N-1 security criterion  benders  reconfiguration
基金项目:
Author NameAffiliationE-mail
Tan Huijuan* School of Electric Power Engineering,South China University of Technology 1844518970@qq.com 
Jing Zhaoxia School of Electric Power Engineering,South China University of Technology zxjing@scut.edu.cn 
Chen Dapeng School of Electric Power Engineering,South China University of Technology epdpchen@mail.scut.edu.cn 
Hits: 1592
Download times: 453
中文摘要:
      电力市场的发展进入现货市场阶段,对区域间输电容量在线评估提出新的要求。利用benders算法求解N-1可用传输容量问题,大幅度降低计算维度,但是也容易产生过矫正、振荡等问题。仅考虑电网的N-1可靠性,忽略下级电网联络线的负荷转供能力,计算结果过于保守,影响电力市场中断面处的交易量。文中提出一种基于benders算法的ATC计算新方法。分析220kV片区电网输电容量时考虑到110kV高压配电网重构对潜在供电能力的挖掘作用。对N-1安全故障进行网络重构,在不增加问题复杂度的前提下,提高区域输电容量,用benders分解法降低问题求解维度,节约计算时间,适用于在线分析。以IEEE30节点算例进行仿真,结果表明计及高压配电网重构的多片区整体ATC要高于无重构能力的片区ATC。
英文摘要:
      The electricity market develop into the spot market stage, requiring higher inter-regional available transmission capacity on-line assessment require. The use of benders algorithm to solve the N-1 available transmission capacity problem, significantly reducing computing dimensions, but also proning to over-correction, oscillation and other issues. Only considering the N-1 reliability of the power grid, ignoring the lower-level power grid reconfiguration, the calculation result is too conservative, reducing the transaction volume in the cross-section. This paper presents a new method of ATC calculation based on benders algorithm. The ATC of 220kV area is analyzed taking into account of the excavation of potential power supply capacity of 110kV high voltage distribution network reconfiguration. The network reconstruction of N-1 security fault is carried out, and the ATC is improved without increasing the complexity of the problem. The problem is solved by benders decomposition method, which saves the calculation time and is suitable for on-line analysis.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd