Statcom对多馈入直流输电系统换相失败恢复过程的影响
Effect of statcom on recovery process of commutation failure in multi-infeed HVDC systems
Received:February 22, 2019  Revised:February 22, 2019
DOI:10.19753/j.issn1001-1390.2020.13.010
中文关键词: 多馈入直流输电  换相失败  Statcom  稳定运行  恢复能力
英文关键词: MIDC, commutation  failure, Statcom, stable  operation, recovery  ability
基金项目:
Author NameAffiliationE-mail
Li Xumin* Shanghai University of Electric Power 956955806@qq.com 
Gu Danzhen Shanghai University of Electric Power gudanzhen@shiep.edu.cn 
Yang Xiu Shanghai University of Electric Power yangxiu721102@126.com 
Zhao Dandan Shanghai Municipal Electric Power Company Electric Power Research Institute zhaodd@163.com 
Cui Yong Shanghai Municipal Electric Power Company Electric Power Research Institute yongzhe@163.com 
Zhang Sujie State Grid Pudong Power Supply Company,SMEPC 13611770740@163.com 
Hits: 1815
Download times: 553
中文摘要:
      多馈入直流输电系统(MIDC)可以实现大容量的功率传输,运行方式也更加灵活,但同时也增加了系统的复杂程度,带来的问题也不少。换相失败是常见的故障,会造成系统直流电流增大、换流母线过电压,除了会在本回路造成多次后续的换相失败外,更严重时还会影响到其他回路,使多条回路同时发生换相失败,引发直流闭锁。因此,换相失败后的恢复问题普遍受到人们关注,如何把换相失败的时间及范围控制到最小关系着整个多馈入系统能否稳定运行。文章提出了静止无功补偿器Statcom接入系统等效加强了交流系统的强度,扩大了系统的稳定运行区域,从而可以达到改善换相失败后的恢复过程的目的。
英文摘要:
      MIDC can realize large-capacity power transmission and flexible operation,but it also increases the complexity of the system and brings more problems.As a common fault,commutation failure can cause the increase of DC current and overvoltage of converter busbar.It will cause both local commutation failure and concurrent commutation failure.Therefore,the recovery problem has been generally concerned.How to control the time and range of commutation failure to the minimum can affect the entire system.The paper proposes that Statcom can add strength of AC system and expand the stable operating area so as to improve the recovery process after the commutation failure.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd