文章摘要
时域有限差分的配电线路耦合雷电过电压求解及其空间变化特征分析
Analysis of Spatial Variation Characteristics and Calculation of Coupled Lightning Overvoltage of Grid Line Based on FDTD
Received:March 18, 2019  Revised:March 18, 2019
DOI:10.19753/j.issn1001-1390.2019.011.007
中文关键词: 配电线路  FDTD  过电压  电荷  空间
英文关键词: Distribution Lines  FDTD  Overvoltage  Charge  Space
基金项目:
Author NameAffiliationE-mail
HanHai''an* Shanxi Electric Power Corporation Metering Center of SGCC 645888511@qq.com 
Hits: 1497
Download times: 771
中文摘要:
      电力系统中,配电线路一般裸露空气中,极易遭受雷电过电压侵害造成供电中断。针对配电线路耦合过电压的空间分布特征问题,采用时域有限差分方法(FDTD)对雷击点相对于配电线路中点、端点位置处的雷电感应过电压进行计算,从而对耦合的雷电过电压峰值时间及空间变化趋势进行研究。结果表明:雷击点处于配电线路中部时,产生峰值28.07kV的雷电过电压,且线路中点位置处束缚的感应电荷最多,随后由中点迅速地向线路两端移动。而雷击点处于线路两端时,产生峰值32.74kV的雷电感应过电压。
英文摘要:
      In the power grid, Power distribution lines are usually exposed in the air and vulnerable to power supply interruption caused by lightning induced overvoltage.About the spatial distribution characteristics of coupling overvoltage of the transmission line, the FDTD is used to simulate the Lightning Induced Overvoltage on the location of the lightning point relative to the middle point and the end point of the distribution line, and the peak time and the spatial trend of the overvoltage are studied. The research shows that when lightning strikes onthe middle part of grid line, the peak value of the overvoltage is 28.07kV. The induced charge of the neutral point at the middle of the line is the largest, and the bound electric charge at the midpoint position moves rapidly to the two ends. The over voltage peak of the lightning stroke relative to the end point of the line is 32.74kV.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd