• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于功效系数法的接触器最佳合闸相角研究
Research on optimal closing phase angle of contactor based on efficacy coefficient method
Received:April 11, 2019  Revised:April 24, 2019
DOI:10.19753/j.issn1001-1390.2020.17.003
中文关键词: 接触器  合闸性能  最佳合闸相角  曲线拟合  功效系数法
英文关键词: contactor  closing performance  optimal closing phase angle  curve fitting  efficacy coefficient
基金项目:
Author NameAffiliationE-mail
Lin Zhijia* School of Information and Control Engineering,China University of Mining and Technology 18361241816@163.com 
Hits: 1211
Download times: 434
中文摘要:
      为了研究不同合闸相角对接触器合闸性能的影响,采用Ansoft Maxwell为CJX1-63型接触器建立了有限元模型,通过对模型的动态特性仿真,得到了不同合闸相角对铁芯吸合速度指标以及合闸时间指标的影响,然后使用Matlab进行仿真数据曲线拟合,得到了两指标与合闸相角的具体函数关系式,最后采用功效系数法构建了综合评价函数,求得最佳合闸相角值。实验表明,在最佳合闸相角下完成合闸,接触器的合闸碰撞以及触头弹跳可以得到较大抑制,合闸性能可以得到较大优化。
英文摘要:
      In order to study the influence of different closing phase angles on the closing performance of contactor, the finite element model of CJX1-63 contactor was established by Ansoft Maxwell. The dynamic characteristics of the model were simulated, and the effects of different closing phase angles on the core closing speed and closing time were obtained. Then, the function relationship between the two indexes and the closing phase angle was obtained by used MATLAB to fit the simulation data curve. Finally, the double-objective comprehensive evaluation function was constructed by used the efficiency coefficient method, and the optimal closing phase angle was obtained. Experiments showed that when the closing phase angle was optimized, the closing collision and contact bounce of contactor could be restrained and the closing performance could be greatly optimized.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd