文章摘要
自适应下垂控制的三电平DC/DC并联均流方法研究
Study on adaptive droop control of parallel current-sharing method for Three-level DC/DC
Received:April 23, 2019  Revised:May 06, 2019
DOI:
中文关键词: 三电平DC/DC变换器  自适应下垂控制  多模块并联  功率均分
英文关键词: Three-level DC/DC, Adaptive droop control, Multiple module parallel, Power-sharing
基金项目:基金项目:国家电网有限公司总部科技项目资助(SGHADK00PJJS1700210),
Author NameAffiliationE-mail
Li Ruisheng XJ Group Corporation ruishengl@139.com 
Guo Baofu XJ Group Corporation 851990293@qq.com 
Zhang Peng* XJ Group Corporation xjgc_zhangpeng@qq.com 
wangweixing XJ Group Corporation 1014044228@qq.com 
xujun XJ Group Corporation xujun.xjgc@qq.com 
Hits: 1903
Download times: 955
中文摘要:
      分析传统下垂控制的三电平DC/DC变换器多模块并联均流电压偏差较大,且各并联模块功率不均分的原因,提出了一种自适应下垂控制的三电平DC/DC变换器多模块并联均流控制方法。通过实时采集各并联变换器的电压和电流,建立变换器下垂系数与负荷功率之间的数学模型,自适应调整下垂系数使直流母线电压跟随给定值。构建直流微电网仿真模型,在相同工况下利用MATLAB/Simulink软件平台,仿真分析传统下垂控制和自适应下垂控制对三电平DC/DC变换器多模块并联直流母线电压降落和功率分配进行对比分析,验证了自适应下垂控制对三电平DC/DC变换器多模块并联的可行性,实现了不同额定功率的三电平DC/DC变换器间的“功率均分”,同时极大的改善了由于线路阻抗导致的电压降,提高了直流母线的电能质量。
英文摘要:
      Based on the analysis of the reasons the voltage deviation of the conventional Three-level DC/DC multi-module parallel current-sharing method is large and the power of each parallel module is not power-sharing, study on adaptive droop of parallel current-sharing method for Three-level DC/DC is proposed. By collecting the voltage and current of each parallel converter in real time, the mathematical model between the droop coefficient of the converter and the load power is established, and the droop coefficient is adjusted adaptively to make the DC bus voltage follow the given value. Build simulation model of DC micro power grid under the same conditions using MATLAB/Simulink software platform, the simulation analysis of traditional drooping droop control and adaptive control method of Three-level DC/DC module in parallel DC bus voltage drop and power allocation were analyzed, verified the sagging adaptive control method is used for more than Three-level DC/DC module in parallel, to realize the different between the Three-level DC/DC converter power rating “power-sharing”, at the same time greatly improve the voltage drop caused by the line impedance, enhances the power quality of DC bus.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd