• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于五次谐波和混沌系统的谐振接地系统故障选线
Fault line selection of resonant grounding system based on fifth harmonic and chaotic system
Received:June 26, 2019  Revised:June 26, 2019
DOI:10.19753/j.issn1001-1390.2022.01.024
中文关键词: 消弧线圈  电容电流突变量  5次谐波分量  Duffing振子系统  相轨迹
英文关键词: arc suppression coil, capacitance current sudden change, 5th harmonic component, Duffing oscillator system, phase trajectory
基金项目:
Author NameAffiliationE-mail
Xue Tailin Department of Electrical Engineering, Shanxi University, Taiyuan 030000, China 13803434745@163.com 
Jin Erwei* Department of Electrical Engineering, Shanxi University, Taiyuan 030000, China jinerweihao@163.com 
Wu Jie Department of Electrical Engineering, Shanxi University, Taiyuan 030000, China 18334786551@163.com 
Hits: 2032
Download times: 537
中文摘要:
      单相接地故障在中性点经消弧线圈接地系统中发生的概率最大,并且接地点的电气故障特征较弱,选线难度大。不同线路的对地电容电流突变量的5次谐波分量的幅值和相位特征差异明显,通过分析比较非故障线路和故障线路之间的这些差异,提出基于电容电流突变量的5次谐波分量和Duffing振子检测原理相结合的选线方法,将每条线路各相的电容电流突变量作为外驱动力加入到Duffing振子系统中,观察本线路各相的相轨迹状态变化的一致性,便可选出故障线路,Matlab仿真结果表明该算法有较高的准确性。
英文摘要:
      The single-phase grounding fault has the highest probability of occurrence in the grounding system of the arc suppression coil at the neutral point, and the electrical fault characteristics of the grounding point are weak, so the line selection is difficult. The amplitude and phase characteristics of the 5th harmonic component of the capacitance current mutation of different lines are obviously different. By analyzing and comparing these differences between the non-faulty line and the faulty line, the line selection method combing the 5th harmonic component based on the mutation of the capacitance current and Duffing oscillator detection principle is proposed in this paper. The capacitance current mutation of each phase and each line is added as an external driving force to the Duffing oscillator subsystem, and the consistency of the phase trajectory state changes of each phase of the line is observed. The fault line can be selected, and the Matlab simulation results show that the algorithm has higher accuracy.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd