基于电容电压的并联UPS系统自主控制策略
Autonomous Control Strategy of Parallel UPS System Based on Capacitor Voltage
Received:July 02, 2019  Revised:July 02, 2019
DOI:10.19753/j.issn1001-1390.2021.06.027
中文关键词: 不间断电源  并联  自主控制  均流
英文关键词: Uninterruptible power supply  parallel  autonomous control  current sharing
基金项目:2017年河南省高等学校青年骨干教师培养计划,项目编号:2017GGJS170
Author NameAffiliationE-mail
GUO Beibei* Henan Institute of Technology 3618089117@qq.com 
Hits: 1091
Download times: 425
中文摘要:
      针对并联不间断电源(UPS)系统的均流控制问题,设计了一种新的并联UPS系统自主控制策略。新方案可用于多个三相在线UPS模块的并联电流分配控制。每台UPS控制器将滤波电容的电压参考设计为其自身输出电流的函数进行调节,无需逆变器之间信息交换即可实现自主均流控制。同时,控制器还保证了负载电压的控制精度以及负载扰动下的动态性能。利用两台UPS为主体构成的实验平台对所设计的新型自主控制方案进行了测试。实验结果表明,在不同负载条件下,包括阶跃负载和非线性负载工况下控制器均具有较好的控制效果。
英文摘要:
      Aiming at the current sharing control problem of parallel uninterruptible power supply (UPS) system, a novel autonomous control strategy for parallel UPS system was designed. The new scheme can be used for parallel current sharing control of multiple three-phase online UPS modules. Each UPS controller was based on regulating the voltage reference of the filter capacitor as a function of its own output current, enabling independent current sharing control without the need for information exchange between the inverters. At the same time, the controller also guaranteed the control accuracy of the load voltage and the dynamic performance under load disturbance. The experimental platform composed of two UPSs was used to test the new autonomous control scheme. The experimental results show that the controller had good control effects under different load conditions, including step-load and nonlinear load.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd