文章摘要
区域电网电磁暂态等值及短路电流直流分量分析
Analysis of DC component of electromagnetic transient equivalent and short circuit current in regional power grid
Received:July 10, 2019  Revised:July 10, 2019
DOI:10.19753/j.issn1001-1390.2020.20.002
中文关键词: 直流分量  电磁暂态  时间常数折算  电阻型超导限流器
英文关键词: DC component, electromagnetic transient, time constant conversion, resistive superconducting current limiter
基金项目:
Author NameAffiliationE-mail
hezeyu School of Electrical and Automation, Wwuhan University 1042589569@qq.com 
chenxiaoyue School of Electrical and Electronic Engineering, Hubei University of Technology 278029064@qq.com 
zhangxingzi School of Electrical and Electronic Engineering, Hubei University of Technology 1052922260@qq.com 
wenxishan* School of Electrical and Electronic Engineering, Hubei University of Technology xswen@whu.edu.cn 
zhangfeng State Grid Xinjiang Power co., LTD. zhangfeng@163.com 
kangpengpeng State Grid Xinjiang Power co., LTD. kppkang@163.com 
Hits: 1927
Download times: 440
中文摘要:
      西北电网电源接入密集、电压级差大,容易引起短路电流超标。但常规限流措施会增大短路电流直流分量的衰减时间,影响断路器的开断能力。文中针对我国西北某大级差、电源密集型电网,搭建了多节点复杂电网发生短路时电磁暂态的等值简化计算模型。在该模型的基础上研究了短路电流直流分量对断路器开断能力的影响,分析了直流分量衰减时间常数折算的方法,并在采取常规限流措施的基础上计算了加装电阻型超导限流器对超标厂站直流分量的抑制效果。结果表明:直流分量的衰减时间常数不能直接作为断路器选型的依据,需要将其折算至标准规定的试验基准值下;电阻型超导限流器可以有效地抑制加装位置附近回路的短路电流直流分量,加装后时间常数下降25%左右,但是对电气距离较远的厂站抑制作用较弱。文中的结论能为断路器的合理选型以及限流新技术的应用提供参考意义。
英文摘要:
      The current situation of dense power supply and large voltage level difference in northwest power grid is easy to cause short-circuit current overshoot. The commonly used current limiting measures will increase the attenuation time constant of the DC component of the short circuit current and affect the breaking capacity of the circuit breaker. This paper presents a simplified model of electromagnetic transient in the case of short-circuit in a complex multi-node power grid with large voltage level difference and intensive power supply in northwest China. On the basis of this model, the influence of DC component on the breaking capacity of circuit breakers is studied, the method of time constant conversion of DC component of short-circuit current is analyzed, and the restraining effect of resistance superconducting current limiter on short-circuit current of overstandard factory station is calculated. The results show that the decay time constant of the DC component needs to be converted to the test base value specified in the standard; Resistive superconducting current limiter can reduce the DC component time constant of the short-circuit current in the circuit near the installation location by about 25%, but it has a weak inhibition effect on the plant station with a long electrical distance. The conclusions in this paper can provide reference significance for the rational selection of circuit breakers and the application of new current limiting technology.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd