并网变流器有限控制集模型预测控制
Finite Control Set Model Predictive Control for LCL Filter Grid-Connected Converters
Received:July 18, 2019  Revised:July 18, 2019
DOI:10.19753/j.issn1001-1390.2020.21.010
中文关键词: 变流器  有限控制集  模型预测控制  主动阻尼
英文关键词: Converter  finite control set  model predictive control  active damping
基金项目:1、国家自然科学基金资助项目(51277103) 2、国家重点研发计划资助项目(2018YFB0904500) 3、国网河南省电力公司科技项目(6224TY01900GK2019)
Author NameAffiliationE-mail
LEi junwei State Grid Henan Electric Power Company leijunwei@ha.sgcc.com.cn 
ZHAO Jian* State Grid Henan Electric Power Company Electric Power Research Institute 1956437014@qq.com 
LIU hao State Grid Henan Electric Power Company Electric Power Research Institute liuhaoepri@139.com 
majianwei 111 11@126.com 
sunqian State Grid Henan Electric Power Company Electric Power Research Institute 111@126.com 
WAN yuxiang Department of Electrical Engineering of Tsinghua University wanyx13@qq.com 
Hits: 2077
Download times: 469
中文摘要:
      为了提高带LCL滤波器的并网变流器的控制性能,设计了一种新型的有限控制集模型预测控制(FCSMPC)策略。交直流变流器采用LCL滤波器接入电网时可带来诸多优点,但也存在电网电流谐振,以及控制复杂度增加的问题。新方案通过将主动阻尼算法融合进FCSMPC控制器中可消除电网电流低次谐波,并降低对电网电压失真的敏感度。使用并网变流器实验平台进行新控制策略的稳态和瞬态测试,以及电网电压扰动下的测试。实验结果表明,所开发的新型控制方案能在电网电压失真条件下降低电网电流谐波含量,并具有较好的动态性能和鲁棒性。
英文摘要:
      In order to improve the control performance of the grid-connected converter with LCL filter, a new finite control set model predictive control (FCSMPC) strategy was designed. AC/DC converters can bring many advantages when using LCL filters to connect to the grid, but there were also problems of grid current resonance and increased control complexity. The new scheme eliminated grid current low-order harmonics and reduces sensitivity to grid voltage distortion by incorporating active damping algorithms into the FCSMPC controller. The steady-state and transient tests of the new control strategy and the test under grid voltage disturbances were carried out using the grid-connected converter experimental platform. The experimental results showed that the new control scheme developed reduces the current harmonic content of the grid under the condition of grid voltage distortion, and has good dynamic performance and robustness.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd