• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于混合储能系统的高电压穿越控制策略
High Voltage Traverse Control Strategy Based on Hybrid Energy Storage System
Received:August 01, 2019  Revised:August 10, 2019
DOI:10.19753/j.issn1001-1390.2022.03.016
中文关键词: 双馈感应发电机组  高电压穿越  混合储能  改进控制策略  暂态分析
英文关键词: doubly  fed induction  generator, high  voltage ride  through (HVRT), hybrid  energy storage, improved  control strategy, hybrid  energy storage, transient  analysis
基金项目:国家自然科学基金 51767024,国家自然科学基金
Author NameAffiliationE-mail
Jiang Ziao* College of Electrical Engineering,Xinjiang University 1178528384@qq.com 
Cui Shuangxi College of Electrical Engineering,Xinjiang University 1178528384@qq.com 
Hits: 2215
Download times: 357
中文摘要:
      针对双馈机组高电压穿越问题,为抑制直流母线电压波动,文中采用蓄电池—超级电容混合储能的拓扑结构。并对储能系统提出一种自动识别和切换的四种充放电工作模式,四种模式是由母线电压的 3个阈值分成的。网侧变流器传统控制忽略了转子电流对直流母线的冲击,提出前馈补偿来优化有功电流的参考值。转子侧变流器传统控制忽略了定子磁链对有功和无功功率的影响,提出对功率外环增加前馈补偿分量来优化控制。matlab/simulink中分别建立传统控制策略和改进控制策略两种模型,在相同的工况下,仿真结果表明该方法在电网故障时,能更有效抑制直流母线过电压,有效提升了高电压穿越能力。
英文摘要:
      
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd