• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
分数阶混沌系统风机间歇故障变幅值检测方法
Wind turbine intermittent fault amplitude change detection method based on Fractional Chaotic System
Received:August 09, 2019  Revised:August 09, 2019
DOI:10.19753/j.issn1001-1390.2020.04.018
中文关键词: 间歇故障  分数阶  混沌系统  幅值变化  大尺度周期状态
英文关键词: intermittent  fault, fractional  order, chaotic  system, amplitude  change, the  large scale  periodic state
基金项目:国家自然科学基金项目( 项目编号)
Author NameAffiliationE-mail
Gao Bingpeng Engineering Research Center of Education Ministry for Renewable Energy Power Generation and Grid Technology,College of Electrical Engineering,Xinjiang University gbp_xd@sina.com 
Wang Weiqing* Engineering Research Center of Education Ministry for Renewable Energy Power Generation and Grid Technology,College of Electrical Engineering,Xinjiang University 1364948453@qq.com 
Hits: 1552
Download times: 556
中文摘要:
      风力发电机的特殊工况使得对其间歇故障的成长检测十分困难,针对这个问题,文中提出了一种微小故障幅值变化检测方法,通过实验寻找微小故障幅值与大尺度周期状态分数阶混沌系统内置信号振幅之间的关系,采用密度均值算法对Duffing系统临界大尺度周期状态的庞加莱截面数据点进行计算,得出离群值并判断系统是否进入大尺度周期状态,自动完成微小故障不同幅值的检测,实验结果证明该方法可行、可靠,为风力发电机微小故障检测提供一个新的思路。
英文摘要:
      Due to the special working condition of the wind turbine, it is very difficult to detect the weak intermittent fault growing state. In order to solve this problem, a kind of weak fault amplitude change detection method is proposed in this paper. First, the relationship between the amplitude of weak intermittent fault and the built-in signal amplitude of the large scale periodic status in the fractional order chaotic system is found through the experiment. Second, density mean algorithm was used to calculate poincare section data points of critical large-scale periodic state of Duffing system. The outliers are obtained and the system is judged to be in a large scale periodic state, and then automatic detection of different amplitudes of weak fault is completed. Last, the simulation results show that the method is feasible and reliable. This method provides a new idea for the theoretical research of intermittent fault.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd