• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
含分布式光伏发电的中压配电网电压控制策略
Voltage control strategy for medium voltage distribution network with distributed photovoltaic generators
Received:October 21, 2019  Revised:October 21, 2019
DOI:10.19753/j.issn1001-1390.2022.05.019
中文关键词: 分布式光伏并网  电压越限  电压控制  无功/有功调节
英文关键词: grid-connected distributed photovoltaic, voltage violation, voltage reguration, Reactive/active power regulation
基金项目:国网云南省电力公司科技项目
Author NameAffiliationE-mail
HE XIN YU Changsha University of Science and Technology 1132768517@qq.com 
chen zhong Changsha University of Science and Technology 2459100334@qq.com 
liu xing* Changsha University of Science and Technology 1254155352@qq.com 
zhang te neng Changsha University of Science and Technology 915519043@qq.com 
chen li jie Changsha University of Science and Technology 542528134@qq.com 
Hits: 1941
Download times: 393
中文摘要:
      随着分布式光伏发电并网规模的不断扩大,由光伏发电功率与负荷之间不平衡引发的逆向潮流导致的电压越限问题日益受到关注。在光伏接入点的电压分析及无功/有功调压分析的基础上,提出了无功/有功协调控制策略,通过光伏逆变器的无功输出补偿及光伏发电量优化管理实现配电网节点电压的控制。仿真分析结果表明,该策略能在兼顾光伏利用效率和经济性的同时,较好地解决含分布式光伏发电的配电网的电压越限问题。
英文摘要:
      With the increasing scale of grid-connected distributed photovoltaic power generation system, the problem of voltage violation, which is resulted from the reverse power flow due to the imbalance between power and load, is a matter of great concern. On the basis of analyzing voltage and active / reactive voltage regulation of photovoltaic access points, the reactive / active coordinated control strategy is proposed. The node voltage is controlled through compensating the reactive output compensation of photovoltaic inverter and optimizing photovoltaic power generation. The simulation results show that the strategy can solve the problem of voltage violation in the distribution network of distributed photovoltaic generators while taking the efficiency and economy of photovoltaic utilization into account.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd