• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
面向智能变电站二次设备的故障诊断方法研究
Research on fault diagnosis method for secondary equipment of Intelligent Substation
Received:November 14, 2019  Revised:November 14, 2019
DOI:10.19753/j.issn1001-1390.2020.03.007
中文关键词: 智能变电站  故障诊断  二次设备  继电保护  测量回路
英文关键词: Intelligent  substation, fault  diagnosis, secondary  equipment, relay  protection, measurement  loop
基金项目:
Author NameAffiliationE-mail
Yin xiangguo* State Grid Ningxia Electric Power Company Inspection Company,Yingchuan fyhl6819@163.com 
Zhang wen State Grid Ningxia Electric Power Company Inspection Company,Yingchuan fyhl6819@163.com 
Luzhiyuan State Grid Ningxia Electric Power Company Inspection Company,Yingchuan fyhl6819@163.com 
Hou feng State Grid Ningxia Electric Power Company Training Center,Yingchuan fyhl6819@163.com 
Wang LeTing GridNT Inc,Jinan fyhl6819@163.com 
Hits: 2012
Download times: 500
中文摘要:
      针对智能变电站二次设备检修和故障隔离工作的高安全风险,本文通过对智能变电站二次设备故障状态的分析,提出了一种智能变电站故障诊断新方法用于继电保护测量回路。在变压器阻抗测量的基础上,利用广义变比建立了故障诊断模型,对极性故障进行分析。并通过仿真对该方法的有效性进行验证。结果表明,该方法可以很好的评估电流电压测量回路的故障状况。该研究为我国智能变电站设备故障诊断的发展提供了参考和借鉴。
英文摘要:
      Aiming at the high safety risk of secondary equipment maintenance and fault isolation in intelligent substation, based on the analysis of secondary system fault state in intelligent substation, this paper proposes a fault diagnosis method of relay protection measuring circuit for secondary equipment in intelligent substation.Based on the measurement of transformer impedance, the fault diagnosis model is established by using the generalized transformation ratio, and the polarity fault is analyzed.The correctness and validity of the method are verified by simulation. The results show that the method can evaluate the fault condition of current and voltage measurement loop very well.This study provides a reference for the development of intelligent substation equipment fault diagnosis in China.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd