• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
混合储能提高光伏低电压穿越控制策略的研究
Research on the control strategy of improving PV low voltage ride through by hybrid energy storage device
Received:November 19, 2019  Revised:November 19, 2019
DOI:10.19753/j.issn1001-1390.2021.05.001
中文关键词: 低电压穿越  光伏并网发电  混合储能
英文关键词: Photovoltaic  grid connected  power generation, hybrid  energy storage, low-voltage  ride through
基金项目:通讯基站风光互补环保型节能辅助供电系统研究(2018CDLZ-28)
Author NameAffiliationE-mail
LI Yongkai College of Electrical Engineering,Sichuan University 307961039@qq.com 
LEI Yong College of Electrical Engineering,Sichuan University 420974017@qq.com 
SU Shihui College of Electrical Engineering,Sichuan University 906464519@qq.com 
Gou Zhengfeng China Tower Co,Ltd Luzhou Company gouzf@chinatowercom.cn 
Yang Dong* Sichuan Provincial Meteorological Service 328189290@qq.com 
Hits: 2773
Download times: 525
中文摘要:
      低电压穿越(Low-voltage ride through,LVRT)是影响光伏并网发电系统稳定运行的重要因素。针对这一现状,本文提出了一种混合储能(hybrid energy storage system,HESS)的控制策略来解决。HESS由蓄电池储能系统(battery energy storage system,BESS)和超导磁储能系统 (Superconducting Magnetic Energy Storage,SMES) 构成。采用低通滤波的方法将不平衡功率分频给HESS分配功率指令。当光伏并网发电系统稳定运行时,光伏逆变器采用PQ控制以最大程度消纳新能源,BESS负责处理低频波动的功率,SMES负责处理高频波动的功率。当出现短路故障时,逆变器采用无功电流注入的策略使逆变器发出无功,此时仅由SMES吸收不平衡功率,BESS不参与运行。MATLAB仿真验证了所提出的控制策略有效性。
英文摘要:
      Low-voltage ride through (LVRT) is an important factor affecting the stable operation of photovoltaic grid connected power generation system. In view of this situation, a hybrid energy storage system (HESS) control strategy was proposed to solve this problem in this paper. HESS consists of battery energy storage system (BESS) and superconducting magnetic energy storage (SMES). The unbalanced power is divided into frequency by using low-pass filter, and the power command is assigned to the HESS. When the photovoltaic grid connected power generation system operates stably, PQ control strategy is adopted for photovoltaic inverter to maximize consumptiveStheseSrenewableSenergies, BESS is responsible for handling the power with low-frequency fluctuation, and SMES is responsible for handling the power with high-frequency fluctuation. In case of short-circuit fault, the inverter adopts the strategy of reactive current injection to make the inverter generate reactive power. During the LVRT, the unbalanced power is absorbed only by SMES, and BESS does not participate in the operation. The effectiveness of the proposed control strategy is verified by MATLAB simulation.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd