• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于测量阻抗变化的含IIDG配电网保护研究
Research on Protection of IIDG Distribution Network Based on Measurement of Impedance Change
Received:November 24, 2019  Revised:November 24, 2019
DOI:10.19753/j.issn1001-1390.2022.12.018
中文关键词: IIDG  配电网  线路测量阻抗  保护
英文关键词: IIDG  distribution network  line measurement impedance  protection
基金项目:基于云南民族道地药材的模式识别相关技术研究
Author NameAffiliationE-mail
ZHOU Shijin School of Electrical Information Engineering,Yunnan Min Zu University 1030707178@qq.com 
HE Jin* School of Electrical Information Engineering,Yunnan Min Zu University 584076220@qq.com 
CAO Lucheng School of Electrical Information Engineering,Yunnan Min Zu University 822646996@qq.com 
LI Ke School of Electrical Information Engineering,Yunnan Min Zu University 741240003@qq.com 
YANG Fan School of Electrical Information Engineering,Yunnan Min Zu University 745266809@qq.com 
Hits: 1398
Download times: 295
中文摘要:
      含IIDG配电网,由于电力电子器件的限流控制以及不同的控制策略,会导致传统保护失效。因此提出了一种通过采用故障前后线路两端测量阻抗幅值的差值变化和线路两端测量阻抗相角差变化为判据的含IIDG配电网保护方案,该方案可以实现配电网区内外故障的有效识别,实现保护的正确动作。方案的有效性通过PSCAD/EMTDC仿真软件进行了验证。
英文摘要:
      Including IIDG distribution network, due to the current limiting control of power electronic devices and different control strategies, traditional protection will be invalid. Therefore, an IIDG distribution network protection scheme based on the difference between the amplitude of the impedance measured at both ends of the line before and after the fault and the phase difference of the measured impedance at both ends of the line is proposed. This scheme can realize the distribution network area. Effective identification of internal and external faults to achieve the correct action of protection.The effectiveness of the solution was verified by the PSCAD/EMTDC simulation software.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd