文章摘要
现行三相电能表计量缺陷及案例分析
Measurement Defects and Case Analysis of Current Three-phase Watt-hour Meter
Received:December 19, 2019  Revised:December 19, 2019
DOI:10.19753/j.issn1001-1390.2022.12.026
中文关键词: 电能表  三相  有功  反向  代数和  正反分计
英文关键词: Watt-hour  meter,three-phase,active  power,reverse,algebraic  sum,calculate  in negative  and positive  ways
基金项目:
Author NameAffiliationE-mail
taoyong* Hefei Power Supply Company of State Grid ty83318@163.com 
liu jinyou Hefei Power Supply Company of State Grid liu_jyo@163.com 
zhao feng Hefei Power Supply Company of State Grid zhaof7913@ah.sgcc.com.cn 
qiao hui Hefei Power Supply Company of State Grid qiaoh3065@ah.sgcc.com.cn 
Hits: 1006
Download times: 322
中文摘要:
      基于对现行三相电能表工作机理和运行情况的深入分析,文章指出三相电能表存在设计缺陷,并进行典型案例分析,提出改进措施。文章经分析测试,发现当出现有反向电量时,现行三相电能表对分布式发电上网、错接线、线损计算等方面存在计量缺陷,电能表无法真实、准确计量实际正反向电量,造成结算错误、差错电量及线损计算错误等。文章对电能表计量的准确性、真实性及功能提升有较大意义。
英文摘要:
      Based on an in-depth analysis of the working mechanism and operation of the current three-phase Watt-hour meter, the paper points out the design defects of the three-phase Watt-hour meter, analyzes the typical cases and proposes the improvement measures. Through analyzing and testing, when there is three-phase reverse active electricity, it is found that the current three-phase Watt-hour meter has measurement defects on distributed generation Internet connection, wrong wiring, line loss calculation and other aspects, and that it cannot accurately measure the actual forward and backward electricity, resulting in settlement errors, wrong electricity amount and inaccurate line loss, etc. This paper is of great significance to the accuracy of measurement and settlement and the improvement of the function of Watt-hour meter.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd