智慧能源站“多站融合”工程中交直流微网系统研究
Research on AC/DC micro-grid system in “multi-station fusion” project of smart energy station
Received:December 25, 2019  Revised:December 25, 2019
DOI:DOI: 10.19753/j.issn1001-1390.2022.06.004
中文关键词: 泛在电力物联网  智慧能源站  多站融合  交直流微网  储能单元
英文关键词: ubiquitous power Internet of things, smart energy station, multi-station integration, AC/DC micro-grid, energy storage unit
基金项目:国家自然科学基金项目(51607068);
Author NameAffiliationE-mail
Zhou Xing* Electric Power Development Research Institute CEC,Beijing stanjoe@163.com 
Liu Jiangmin Electric Power Development Research Institute CEC,Beijing 18701602896@163.com 
Chu Nong Electric Power Development Research Institute CEC,Beijing 13811591322@163.com 
Gao Yajing Electric Power Development Research Institute CEC,Beijing 13722282201@163.com 
Song Qipeng China Electric Power Research Institute 15901171913@163.com 
Hits: 1963
Download times: 382
中文摘要:
      文中通过分析变电站、数据中心、储能站、充(换)电站等传统供电方式和负荷特性,研究出智慧能源站“多站融合”工程中交直流微网供电系统框架结构。通过分析交直流微网中储能单元与数据中心设计的深度融合,提出了储能单元应用于数据中心服务器供电的3种模式,并提出适用于直流微网的接线形式,优化了柴油发电机和UPS系统的配置和运行方式。在保证可靠性的前提下,降低了建设成本和运维成本,提高了电源系统的综合能效,为后续智慧能源站“多站融合”试点工程的规划设计和运行提供参考。
英文摘要:
      This paper analyzed the traditional power supply mode and load characteristics of substations, data centers, energy storage stations, charging (replacement) power stations, etc., and the framework structure of AC/DC micro-grid power supply system in the project of "multi-station fusion" of smart energy stations is studied. According to study the deep integration of the energy storage unit and the design of the data center in AC/DC micro-grid, three power supply modes of energy storage unit applied to the data center server are proposed, and the wiring form suitable for DC micro-grid is proposed, which optimizes the configuration and operation mode of the diesel generators and the UPS system. On the premise of ensuring the reliability of the power supply of each system, the construction cost and operation costs are reduced, and the overall energy efficiency of the power system is improved, which provides a reference for the design and operation of “multi-station integration” projects of smart energy stations.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd