• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
考虑多影响要素的分布式光伏接入配电网馈线位置及容量研究
The location and capacity research of distributed photovoltaic integrated in distribution network feeder with multiple influence factors considered
Received:December 25, 2019  Revised:December 25, 2019
DOI:10.19753/j.issn1001-1390.2021.05.019
中文关键词: 分布式光伏  配电网馈线  电压波动  影响因素  典型并网场景
英文关键词: distributed  photovoltaic, distribution  network feeder, voltage  fluctuation, influence  factor, typical  integration scene
基金项目:
Author NameAffiliationE-mail
Qu Gaoqiang* Economic and Technological Research Institute of NingXia Electric Power Company,Yinchuan qgq300@163.com 
Hits: 1882
Download times: 801
中文摘要:
      本文针对光伏电源出力的波动性可能带来的配电网的电压波动问题,结合光伏电源一次能源特性,开展了分布式光伏对配电网馈线电压波动影响机理的一般性分析,提出了10kV馈线可接入的最大光伏容量的估算公式;在此基础上总结了包括接馈线结构,线路型号、供电范围、线路负荷分布等在内的并网相关影响因素,构建了综合考虑所提影响因素的分布式光伏接入配电网馈线典型场景,基于所提场景的仿真分析,给出了分布式光伏接入配电网馈线位置的推荐方案以及布式光伏接入馈线的各影响因素影响大小的评估结果。
英文摘要:
      Focused on voltage fluctuation caused by photovoltaic power sources output volatility, the general analysis of voltage fluctuation influence mechanism triggered by distributed photovoltaic is performed and the estimation formula of photovoltaic maximum access capacity in 10kV feeder are presented. On the basis, the relevant influence factor is summarized with feeder structure, feeder type, feeder length and load distribution included. The typical integration scenes of distributed photovoltaic are illustrated. Based on the simulation of these scenes, they are provided that the recommendation of distributed photovoltaic integration location in feeder and the influence factor evaluation results of photovoltaic integration.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd