• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
链式STATCOM在双馈风电场中的谐波抑制研究
Application of chained STATCOM based on harmonic suppression ability in doubly-fed wind farm
Received:December 28, 2019  Revised:December 28, 2019
DOI:10.19753/j.issn1001-1390.2020.04.010
中文关键词: 双馈风电场  STATCOM  谐振控制器  谐波抑制
英文关键词: Doubly-fed  wind farm, STATCOM, Resonant  controller, Harmonic  suppression
基金项目:国家自然科学基金项目( 51667018)
Author NameAffiliationE-mail
Xing Chen School of Electrical Engineering,Xinjiang University 1113202450@qq.com 
Zhang Xinyan* School of Electrical Engineering,Xinjiang University xc18203424465@163.com 
Zhou Peng School of Electrical Engineering,Xinjiang University 1540531279@qq.com 
Tong Tao School of Electrical Engineering,Xinjiang University 1378104278@qq.com 
Hits: 1092
Download times: 397
中文摘要:
      针对双馈风电场存在谐波污染问题,本文提出将具有谐振控制器功能的链式STATCOM应用于双馈风电场。分析了具有谐振控制器功能的链式STATCOM数学模型,然后对谐振控制器的控制特性进行改进,提出了一种具有低次谐波抑制作用的PIR-VPI混合控制方法。研究了该混合控制方法的工作原理,并建立数学模型,对参数进行设计,在MATLAB中进行验证。理论分析和仿真结果验证了此方案应用于双馈风电场中谐波抑制的有效性。
英文摘要:
      Aiming at the problem of harmonic pollution in doubly-fed wind farms, this paper proposes to apply a chained STATCOM with a resonance controller function to doubly-fed wind farms. The mathematical model of the chain STATCOM with the function of the resonant controller is analyzed, and then the control characteristics of the resonant controller are improved. A PIR-VPI hybrid control method with low harmonic suppression is proposed. The working principle of the hybrid control method is studied, and a mathematical model is established, and the parameters are designed and verified in MATLAB. Theoretical analysis and simulation results verify the effectiveness of this scheme in harmonic suppression in doubly-fed wind farms.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd