• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
35kV配电线路绝缘子串与多断点灭弧防雷间隙雷电冲击绝缘配合研究
Lighting Insulating Co-ordination Between Insulator String and Multiple-break Arc-extinguishing Lighting Protection Gap of 35 kV Transmission Line
Received:January 03, 2020  Revised:January 03, 2020
DOI:10.19753/j.issn1001-1390.2022.05.014
中文关键词: 绝缘子串  灭弧间隙  雷电冲击  伏秒特性  绝缘配合
英文关键词: insulator string  arc-extinguishing gap  lightning impulse  voltage-time characteristics  insulating co-ordination
基金项目:国家自然科学基金项目( 51467002)
Author NameAffiliationE-mail
mengweihang* Guangxi University mengweihang24@163.com 
Wang Jufeng Guangxi University 993138826@qq.com 
Huang Shangshi Guangxi University huangshangshi93@163.com 
Li Zijian Guangxi University 634545216@qq.com 
Hits: 1450
Download times: 366
中文摘要:
      实验仿真分析表明,多断点灭弧防雷间隙能有效降低35 kV配电线路雷击跳闸率,但目前暂无对多断点灭弧防雷间隙和绝缘子的雷电冲击绝缘配合的研究。因此,对35 kV玻璃、复合绝缘子串及不同间隙距离的多断点灭弧防雷间隙进行雷电冲击特性和伏秒特性的实验研究。实验结果表明:多断点灭弧防雷间隙能够在雷击后有效保护绝缘子;有效相同间隙距离下,多断点灭弧防雷间隙的绝缘水平要高于并联间隙;通过实验给出多断点灭弧防雷间隙的有效保护距离。此结论可为安装多断点灭弧防雷间隙的工程提供参考。
英文摘要:
      The simulation results show that multiple-break arc-extinguishing lightning protection gap can effectively reduce the lightning tripping rate of 35 kV transmission lines, but there are few studies on lighting insulating co-ordination between insulator string and multiple-break arc-extinguishing lighting protection gap of 35 kV transmission line. Therefore, the lightning impulse characteristics and voltage-time characteristics of a 35 kV glass insulator string, a 35 kV composite insulator string and their multiple-break arc-extinguishing lighting protection gap with different clearance distances were experimentally studied. The experimental results show that multiple-break arc-extinguishing lightning protection gap can effectively protect insulator after lightning stroke; the insulation level of the multiple-break arc-extinguishing lightning protection gap is higher than that of the parallel gap devices at the same gap distance; the effective gap distance of multiple-break arc-extinguishing lightning protection gap is given by experiment This conclusion can provide reference for the engineering of installing multiple-break arc-extinguishing lightning protection gap.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd