• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
电气设备长间歇性局部放电检测系统研究
Research on Long-interval Sparse Partial Discharge Detection Systemfor Electrical Equipment
Received:March 03, 2020  Revised:March 08, 2020
DOI:10.19753/j.issn1001-1390.2021.07.024
中文关键词: 带电检测  重症监护  电气设备  云平台  长间歇性
英文关键词: live detection  intensive care  electrical equipment  cloud platform  long-interval sparse
基金项目:
Author NameAffiliationE-mail
NIU Bo* Power Research Institute of State Grid Ningxia Power Co,Yinchuan svc_hvdc@163.com 
Hits: 1642
Download times: 434
中文摘要:
      为降低外界干扰在带电检测与在线监测中对电气设备内部发生的长间歇性、潜伏性局部放电的误判,避免因绝缘击穿而导致的设备故障停电。本文首先对长间歇性局部放电的放电特性进行研究,之后在现有带电检测与在线监测基础上,设计了一套便携式长间歇性局部放电监测系统。该系统不仅可以完成设备内部不同频带局部放电信号的采集与放电缺陷的初步定位,而且在云端可以完成局部放电缺陷发展状态的动态跟踪。试验及现场应用结果证明所设计长间歇性局部放电监测系统可以完成电气设备内部局部放电缺陷的长期跟踪,并通过实时的数据更新、在线数据分析,可以为异常设备绝缘状态进行评估。
英文摘要:
      To reduce misinterpretations of long intermittent and latent partial discharges that occur inside electrical equipment during live detection and online monitoring, avoid equipment failure and power failure due to insulation breakdown. This paper first studies the discharge characteristics of long intermittent partial discharges, and then designs a portable long intermittent partial discharge monitoring system based on existing live detection and online monitoring. This system can not only complete the collection of partial discharge signals in different frequency bands inside the device and the initial positioning of discharge defects, but also can dynamically track the development status of partial discharge defects in the cloud platform. The test and field application results prove that the designed long-interval sparse partial discharge monitoring system can complete the long-term tracking of partial discharge defects in electrical equipment, and evaluate the abnormal equipment insulation status through online data analysis.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd