文章摘要
基于Lagrange插值法的变压器励磁涌流评估与应用
Evaluation and application of transformer inrush current based on Lagrange interpolation method
Received:March 05, 2020  Revised:March 05, 2020
DOI:10.19753/j.issn1001-1390.2020.23.020
中文关键词: Lagrange插值法  变压器  励磁涌流  评估  边界
英文关键词: Lagrange interpolation method  transformer  inrush current  evaluation  Boundary
基金项目:
Author NameAffiliationE-mail
He Zhi-long* China Datang Corporation Science and Technology Research Institute East China Electric Power Test & Research Institute 827012934@qq.com 
Hits: 1414
Download times: 461
中文摘要:
      二次谐波含量是作为判断变压器励磁涌流的主要特征之一。对于一台变压器,影响励磁涌流二次谐波含量因素中合闸角度、铁心磁通饱和点、变压器容量、变压器结构、变压器电压等级是确定的,唯一不确定是剩磁的大小。本文将根据MATLAB建立的模型仿真出来的离散数据,通过Lagrange插值法得到高次非线性插值函数,并画出函数的图形,评估剩磁影响下变压器励磁涌流二次谐波含量的边界范围。本文将基于一起事件案例,证实该方法的实用性和有效性。
英文摘要:
      The second harmonic content is one of the main characteristics of transformer inrush current. For a transformer, the closing angle, the core flux saturation point, the transformer capacity, the transformer structure and the transformer voltage grade are certain, but the remanence is the only uncertain factor. Based on the discrete data simulated by the model established by Matlab, the higher order nonlinear interpolation function is obtained by Lagrange interpolation method, and the graph of the function is drawn, boundary Range for evaluating the second harmonic content of transformer inrush current under the influence of remanence. Based on a case study, this paper proves the practicability and effectiveness of the method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd