• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
针对多点接地故障的变压器铁芯建模优化与电流特征研究
Study on modeling optimization and current characteristics of transformer core for multi-point grounding fault
Received:July 02, 2020  Revised:August 14, 2020
DOI:10.19753/j.issn1001-1390.2023.10.027
中文关键词: 多点接地故障  均匀化  有限元  电流特征
英文关键词: multi-point grounding fault, homogenization, finite element, current characteristics
基金项目:国家重点研发项目(2018YFC1505502-03);成都市科技局(2019-RK00-00155-ZF)
Author NameAffiliationE-mail
Guo Xin* Sichuan University 1048866911@qq.com 
zeng chengbi Sichuan University 857606631@qq.com 
Deng Zirong Sichuan University 1048866911@qq.com 
Miao Hong Sichuan University 1604681549@qq.com 
Bai Wei Sichuan Geshiza Hydropower Development Co.,Ltd. 1048866911@qq.com 
Zhang Zhihui Sichuan Geshiza Hydropower Development Co.,Ltd. 1048866911@qq.com 
Hits: 989
Download times: 264
中文摘要:
      针对变压器铁芯多点接地故障,对接地电流进行研究,提出了一种实际应用上更简便的均匀化建模方法,并验证方法的准确性。同时通过建立变压器铁芯多点接地故障有限元模型,在Maxwell三维瞬态模式下对变压器多点接地故障进行有限元分析计算,探究了变压器铁芯多点接地故障下短路电流特征。
英文摘要:
      Aiming at the multi-point grounding fault of the transformer core, the ground current is studied, and a simpler uniform modeling method in practical application is proposed, and the accuracy of the proposed method is verified. Meanwhile, the finite element model of the transformer core multi-point grounding fault is established. In the Maxwell three-dimensional transient mode, the finite element calculation of the transformer multi-point grounding fault is performed, and short-circuit current characteristics of the transformer core under multi-point grounding fault are analyzed.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd