• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于过渡电阻倾斜角的风电T接双电源系统自适应距离保护方案
Adaptive distance protection scheme of wind power T-connected dual power system based on transition resistance inclination angle
Received:August 11, 2020  Revised:August 21, 2020
DOI:10.19753/j.issn1001-1390.2024.03.019
中文关键词: 风电T接  自适应距离保护  测量阻抗  过渡电阻  过渡电阻倾斜角
英文关键词: wind power T-connection, adaptive distance protection, measurement impedance, transition resistance, transition resistance inclination angle
基金项目:自治区重点实验室开放课题(2018D04005);国家自然科学基金(16670205);教育部创新团队(IRT_16R63);自治区高校科研计划自然科学重点项目(XJEDU2019I009)
Author NameAffiliationE-mail
CHUAN Yun* Engineering Research Center of Education Ministry for Renewable Energy Power Generation and Grid Control,Xinjiang University 1208661140@qq.com 
WANG Weiqing Engineering Research Center of Education Ministry for Renewable Energy Power Generation and Grid Control,Xinjiang University 3064486275@qq.com 
WAN Haiyun Engineering Research Center of Education Ministry for Renewable Energy Power Generation and Grid Control,Xinjiang University 327028229@qq.com 
WU Jiahui Engineering Research Center of Education Ministry for Renewable Energy Power Generation and Grid Control,Xinjiang University 308781253@qq.com 
Hits: 555
Download times: 196
中文摘要:
      针对风电T型接入高压配电网后传统距离保护可能发生误动、拒动的情况,研究相对应的保护方案意义重大。文章推导了风电T接点上、下游测量阻抗表达式,得出其包含的附加阻抗可能会使传统保护装置不正确动作。鉴于此,提出基于过渡电阻倾斜角的风电T接系统自适应距离保护方案。该方案自适应修正测量阻抗使其能跟踪到短路阻抗,有效消除附加阻抗对距离保护的影响。在MATLAB仿真软件中对方案进行仿真验证,结果表明该方案受故障点位置、过渡电阻、电源相位差及风电运行方式影响较小,可有效解决传统距离保护拒动或者误动的问题,提高电网的安全稳定性。
英文摘要:
      In view of the situation that the traditional distance protection may misoperate and refuse to operate after the wind power T-type is connected to the high-voltage distribution network, it is of great significance to study the corresponding protection scheme. First of all, this paper deduces the expressions of measurement impedance of upstream and downstream of wind power T-connection, and concludes that the additional impedance contained in it may make the traditional protection device not operate correctly. In view of this, an adaptive distance protection scheme of wind power T-connection system based on transition resistance inclination angle is proposed in this paper. The scheme can adaptively modify the measurement impedance so that it can track the short-circuit impedance and effectively eliminate the influence of additional impedance on distance protection. Finally, the scheme is verified by MATLAB simulation software. The results show that the proposed scheme is less affected by the fault location, transition resistance, power phase difference and wind power operation mode, which can effectively solve the problem of refusing to operate or misoperation of traditional distance protection, and improve the security and stability of power grid.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd