• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于三次谐波电压注入的扩展混合型MMC运行区域的控制方法
Third harmonic voltage injection based control method with expanding the operation area of ??hybrid MMC
Received:October 16, 2020  Revised:November 01, 2020
DOI:10.19753/j.issn1001-1390.2023.08.027
中文关键词: 混合型MMC  低直流电压  运行区域  三次谐波电压  电容电压均衡
英文关键词: hybrid  MMC, DC  voltage drop, operating  area, third  harmonic voltage, capacitor  voltage balance
基金项目:国家重点研发计划子课题:基于微型同步相量测量的智能配电网运行关键技术研究(2017YFB0902800)
Author NameAffiliationE-mail
liGuanhong College of Electrical and Engineering,Shandong University of Technology liguanhong789@163.com 
LuMaozeng* College of Electrical and Engineering,Shandong University of Technology lumaoz@sdut.edu.cn 
BianDunxin College of Electrical and Engineering,Shandong University of Technology 4654950232@qq.com 
ZhaoYanlei College of Electrical and Engineering,Shandong University of Technology zhaoyanlei01@163.com 
LuMeixue College of Electrical and Engineering,Shandong University of Technology 826174137@qq.com 
Hits: 683
Download times: 295
中文摘要:
      针对低直流电压运行工况下混合型MMC全桥子模块及半桥子模块电容电压不均衡问题,提出了一种基于三次谐波电压注入的改善方法。首先,回顾了子模块电容电压不均衡问题机理,计算出子模块电容电压不均衡问题发生的边界条件以及混合型MMC安全运行区域。然后,定量分析三次谐波电压幅值及初始相位对电容电压的影响规律,并计算出三次谐波电压注入对混合型MMC的运行区域的扩充效果。最后,基于Matlab/Simulink建立了双端仿真模型,验证了所提方法的有效性。
英文摘要:
      Due to the difference in charging and discharging of the full-bridge sub-module and the half-bridge sub-module, the capacitor voltage imbalance may occur when hybrid MMC operates at a reduced DC-link voltage. In this paper, third harmonic voltage injection based control method which can improve the above imbalance is proposed. First, the mechanism of the capacitor voltage imbalance problem is reviewed, and the boundary conditions when the capacitor voltage imbalance problem occurs is deduced. Further, considering of different DC-link voltage drops, the hybrid MMC operating area is calculated. Then, the effect of the third harmonic voltage injection on the capacitor voltage imbalance is analyzed, and the expansion effect on the operating area of ??the hybrid MMC is analyzed quantitatively. Finally, a double-ended simulation model with Matlab/Simulink is established, and the simulation results verify the effectiveness of the proposed method and corresponding analysis.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd