文章摘要
基于现场信号仿真技术的电流互感器误差测试技术研究
Research on current transformer error testing technology based on real power simulation
Received:November 18, 2020  Revised:December 21, 2020
DOI:10.19753/j.issn1001-1390.2021.02.021
中文关键词: 低压电流互感器  实功率  复合误差  仿真
英文关键词: low  voltage current  transformer for  metering, real  power, composite  error, simulation
基金项目:国网上海市电力公司科技项目(52094018002A)
Author NameAffiliationE-mail
Chen Haibin* State Grid Shanghai Electric Research Institute 1040178598@qq.com 
Yang Shunan State Key Laboratory of Electrical Insulation and Power Equipment,Xi’an Jiaotong University,Xi’an 790543027@qq.com 
Chen Liwen State Grid Shanghai Electric Research Institute ChenLiwen@sgcc.com 
Zhen Haohan State Grid Shanghai Electric Research Institute ZhenHaohan@sgcc.com 
Chen Shengze State Grid Shanghai Electric Research Institute ChenShengze@sgcc.com 
Zhang Mengyu State Grid Shanghai Electric Research Institute ZhangMengyu@sgcc.com 
Hits: 1810
Download times: 658
中文摘要:
      针对在计量用低压电流互感器的误差检测中,传统测量方法无法模拟现场实际工况的问题,提出一种基于现场信号仿真技术的电流互感器误差测试方法,并采用实验对其进行验证。首先,将基于高速录波技术,所提取的现场实际工况波形及特征信号,进行数字化分解;然后,利用程控电压源与程控电子负载,搭建信号仿真测试平台,复现现场工况波形,对被试电流互感器进行误差测试,并分解、整理所用波形,形成电流互感器运行误差测试波形库。最后,利用波形库中特征波形,对电流互感器进行误差检测并校准。
英文摘要:
      In order to solve the problem that the traditional measurement method can not simulate the actual working condition in the measurement of low-voltage current transformer error detection, a current transformer error test method based on the field signal simulation technology is proposed and verified by experiments. First of all, based on the high-speed recording technology, the actual working condition waveform and characteristic signal are digitally decomposed. Then, using the program-controlled voltage source and program-controlled electronic load, the signal simulation test platform is built to reproduce the field working condition waveform, and the error test of the tested current transformer is carried out, and the used waveform is decomposed and sorted to form the current transformer operation error test waveform library. Finally, the current transformer error could be detected and calibrated by using the characteristic waveform in the waveform library.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd