• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于电力电子开关的快速调匝式消弧线圈研究
Fast adjustable arc suppression coil based on power electronic switch
Received:December 08, 2020  Revised:January 07, 2021
DOI:10.19753/j.issn1001-1390.2021.05.009
中文关键词: 配电网  供电可靠性  消弧线圈  电力电子开关  改造
英文关键词: distribution  network, power  supply reliability, arc  suppression coil, power  electronic switch, transformation
基金项目:河北省科技支撑计划项目(15212105D)
Author NameAffiliationE-mail
Yang Tingsheng* CNOOC International Ltd yang_tingsheng@sina.com 
Miao Houli CNOOC International Ltd miaohouli@sohu.com 
Li Zhijun Hebei University of Technology zhijun_li@263.net 
Hits: 2059
Download times: 386
中文摘要:
      伊拉克某油田配电系统采用电阻接地形式,由于支线电网所处环境恶劣以及部分设施老化,接地故障频繁,使得油田设备供电可靠性急剧下降。本文针对这一问题提出了一种消弧线圈接地改造技术方案,该方案基于传统调匝式消弧线圈技术,用电力电子开关替代了机械负载开关,以克服原始有载机械开关动态响应差、补偿不及时的问题,同时保留了传统调匝式消弧线圈的经济性、可靠性的特点。多工况MATLAB仿真验证和物理实验证明,本技术方案经济可行、有效,可以实施配电系统的技术改造。
英文摘要:
      The power distribution system of an oil field in Iraq uses resistance grounding. Due to the harsh environment of the branch power grid, the aging of some facilities, and frequent grounding faults, the reliability of the oil field equipment power supply has dropped sharply. To solve this problem, this paper proposes a technical solution for the grounding of the arc suppression coil. The solution is based on the traditional turn-adjustable arc suppression coil technology. The mechanical load switch is replaced by a power electronic switch to overcome the problems of poor dynamic response and delayed compensation of original on-load mechanical switches while retaining the economical and reliable characteristics of traditional turn-adjusting arc suppression coils. Multi-condition MATLAB simulation verification and physical experiments prove that this technical solution is economical, feasible and effective, and can implement the technical transformation of the power distribution system.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd