小电流接地配电网馈线单相接地故障零序阻抗特性分析
The analysis of zero-sequence impedance characteristics of feeder in distribution system with neutral point non-effective grounding
Received:March 25, 2021  Revised:April 14, 2021
DOI:10.19753/j.issn1001-1390.2024.06.008
中文关键词: 小电流接地  暂态  单相接地故障  零序阻抗  仿真
英文关键词: low current grounding system, transient, single-phase earth fault, zero-sequence impedance, simulation
基金项目:国家重点研究发展计划项目(2017YFB0902800);国家电网公司科技项目(SGTYHT/16-JS-198)
Author NameAffiliationE-mail
LI Nana* School of Electrical and Electronic Engineering, Shandong University of Technology linam8@163.com 
WANG Bin State Key Lab of Control and Simulation of Power Systems and Generation Equipments(Dept. of Electrical Engineering, Tsinghua University) binw_ee@tsinghua.edu.cn 
Hits: 561
Download times: 194
中文摘要:
      文章以暂态零序特征为着眼点,从频域角度对小电流接地系统发生单相接地故障后的特性进行详细探讨。从线路入端零序阻抗这一随频率变化的特征量入手,深入挖掘了配电网系统中各馈线零序阻抗的阻抗特性,详细探讨了零序阻抗的幅值、相角随频率的变化规律,并针对不同的中性点接地方式以及线路是否健全加以分析,为更好地利用零序暂态信号,提高故障检测正确率夯实了基础。最后通过PSCAD搭建仿真模型验证了该特性。
英文摘要:
      Based on the transient zero-sequence characteristics, this paper studies the zero-sequence transient characteristics of low current grounding system in frequency domain. Starting from the characteristic variable of zero-sequence impedance at the line inlet which changes with frequency, this paper deeply excavates the impedance characteristics of zero-sequence impedance of each feeder in the distribution network system, discusses the variation law of amplitude and phase angle of zero-sequence impedance with frequency in detail, and analyzes different neutral grounding modes and whether the line is sound or not, so as to make better use of zero-sequence transient signal and improve fault diagnosis The correct rate of detection lays a solid foundation. Finally, a simulation model is built by PSCAD to verify the characteristics.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd