• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
弱联络条件下并网虚拟同步发电机小干扰稳定分析
Analysis of small-signal stability of grid-connected VSG under weak grid connection
Received:June 01, 2021  Revised:June 25, 2021
DOI:10.19753/j.issn1001-1390.2024.09.013
中文关键词: 并网虚拟同步发电机  小干扰稳定性  弱联络
英文关键词: virtual synchronous generator (VSG), small-signal stability, weak grid connection
基金项目:国家电网公司总部科技项目(SGXJ0000TKJS2000166)
Author NameAffiliationE-mail
KE Xianbo Northwest Branch of State Grid Corporation of China 119074735@qq.com 
SUN Yiqian State Grid Xinjiang Electric Power Company 119074735@qq.com 
REN Chong Northwest Branch of State Grid Corporation of China 119074735@qq.com 
WANG Heng State Grid Xinjiang Electric Power Company 119074735@qq.com 
KANG Pengpeng State Grid Xinjiang Electric Power Company 119074735@qq.com 
GAO Ruilin* School of Electrical Engineering, Sichuan University ruilin_gao_scu@163.com 
Hits: 404
Download times: 167
中文摘要:
      文中研究了弱联络条件下并网虚拟同步发电机的小干扰振荡稳定性问题。首先,建立了并网虚拟同步机的简化线性化模型;然后,结合劳斯稳定判据理论,推导了并网虚拟同步机的小干扰稳定性判据。对稳定性判据的进一步分析表明:无论电网强度以及控制参数变动,并网虚拟同步机总能保持稳定运行。所以,弱联络条件不会给并网虚拟同步机带来振荡失稳问题。最后通过仿真算例,演示并验证了理论分析的正确性。
英文摘要:
      This paper analyzes the small-signal oscillation stability of a grid-connected VSG under weak gird connection. Firstly, simplified linearized model of grid-connected VSGs is established. Secondly, based on the Routh stability criterion theory, the small-signal stability criterion of grid-connected VSGs is derived. Further analysis of the stability criterion shows that the grid-connected VSGs can always maintain stable operation when the power grid strength or control parameter varies. Therefore, weak grid connection condition will not cause small-signal instability of grid-connected VSGs. Finally, simulation cases demonstrate and verify the correctness of the theoretical analysis.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd