文章摘要
基于前馈谐波解耦控制的Boost PFC变换器
Boost PFC converter based on feedforward harmonic decoupling control
Received:October 13, 2022  Revised:November 04, 2022
DOI:j.issn1001-1390.2025.08.025
中文关键词: 功率因数校正  谐波补偿  本地配电网  分布式治理
英文关键词: power factor correction(PFC), harmonic compensation, local distribution network, distributed management
基金项目:四川省区域创新合作项目(2021YFQ0006)
Author NameAffiliationE-mail
ZHANG Rongfei School of Electrical Engineering, Sichuan University 849151860@qq.com 
LIU Xueshan* School of Electrical Engineering, Sichuan University xueshan5851@163.com 
WANG Chuntao School of Electrical Engineering, Sichuan University 1040016769@qq.com 
ZHOU Qun School of Electrical Engineering, Sichuan University 2461187280@qq.com 
Hits: 78
Download times: 28
中文摘要:
      电力电子设备在本地配电网的高渗透趋势导致谐波源密集化、分散化、广域化,传统点对点的谐波治理方式存在弊端。基于功率因数校正(power factor correction,PFC)变换器和典型的本地配电网模型,研究了非线性负荷与Boost PFC变换器之间的相互影响,研究结果表明传统峰值电流控制Boost PFC变换器具有一定的谐波补偿能力,但其谐波补偿效果较差;基于此,提出了一种与临界连续峰值电流控制Boost PFC变换器相匹配的前馈谐波解耦控制方法,以实现对本地配电网中非线性负载谐波的自适应补偿;同时,考虑不同的本地配电网工况,阐述了单台Boost PFC变换器的谐波补偿控制环路设计及其谐波补偿能力。最后,搭建了一台基于前馈谐波解耦控制的160 W Boost PFC样机对理论分析进行实验验证,验证了理论分析的正确性与可行性。
英文摘要:
      The high penetration trend of power electronic equipment in local distribution network has led to the concentration, decentralization and wide area of harmonic sources, and the traditional point-to-point harmonic suppression is no longer applicable. Based on the power factor correction (PFC) converter and typical local distribution network model, this paper studies the interaction between nonlinear load and Boost PFC converter. The research results show that the traditional peak current controlled Boost PFC converter has weak harmonic compensation ability. On this basis, a feedforward harmonic decoupling control method matched with the critical continuous peak current controlled Boost PFC converter is proposed to realize the adaptive compensation of nonlinear load harmonics in the local distribution network. Meanwhile, considering different local distribution network conditions, the design of harmonic compensation control loop and the harmonic compensation capability of a single Boost PFC converter are analyzed. Finally, a 160 W feedforward harmonic decoupling controlled Boost PFC prototype is built to verify the theoretical analysis. The results verify the correctness and feasibility of the theoretical analysis.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd