• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于快速检测和速断控制的智能断路器毫秒级保护方案
Msec protection scheme of intelligent circuit breaker based on fast detection and quick break control
Received:October 21, 2022  Revised:November 15, 2022
DOI:10.19753/j.issn1001-1390.2023.04.021
中文关键词: 智能断路器  快速跟踪  速断控制  奇异性检测
英文关键词: Intelligent  circuit breaker,Fast  track,Quick  break control,Singularity  detection
基金项目:南方电网公司科技项目(090000KK52210004)
Author NameAffiliationE-mail
QIU Fangchi* Futian Power Supply Bureau of Shenzhen Power Supply Bureau Co,Ltd szcsg1979@163.com 
LI Jiming Futian Power Supply Bureau of Shenzhen Power Supply Bureau Co,Ltd 861726883@qq.com 
Hits: 854
Download times: 345
中文摘要:
      在低压配电系统中,保护的准确性及实时性直接影响着电力部门和用户的安全及切身利益。智能断路器通过快速跟踪检测技术,对线路短路进行实时监测,并对故障进行快速响应处理。通过对短路突变信息进行奇异性检测分析,提高了保护的准确性与可靠性。基于快速跟踪检测技术的速断控制方法在低压智能断路器可以为需要快速保护的线路或节点提供可靠快速的保护,可以与传统监控系统配合使用,实现低压台区保护功能的升级,也可按台区智能管控的要求进行建设,实现低压台区智能快速保护的目标。通过在现场实际应用,对于大电流短路故障的快速保护响应都能够在18mS内完成,达到了预期的效果并验证了方案的可行性与实用性。
英文摘要:
      In low-voltage distribution system, the accuracy and real-time of protection directly affect the safety and vital interests of power department and users. The intelligent circuit breaker uses the fast tracking and detection technology to monitor short circuits in real time and respond to faults quickly. Through singularity detection and analysis of short-circuit mutation information, the accuracy and reliability of protection are improved. Quick break control method based on the fast track detection technology in low voltage circuit breaker can to protect lines or nodes need to quickly provide rapid and reliable protection, can be used together with the traditional monitoring system, realizes the low pressure area protection function upgrade, also may carry on the construction according to the requirement of the area of intelligent control, realize the goal of low pressure area intelligent fast protection. Through the practical application in the field, the fast protection response to the high-current short-circuit fault can be completed within 18mS, which achieves the expected effect and verifies the feasibility and practicability of the scheme.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd